Other Products
     About Us

©2012 Plenum Innerduct

Abesco Mortar Abesco Fire Mortar-Fire Rated Mortar- Abesco FP-CP30310-Abesco Fire Rated Intumescent Caulk,Abesco FP-CP30350-ASTM E 814 Firestop Products

Abesco Mortar- Fire Rated Mortar-Abesco Fire Rated Mortar is a lightweight mortar compound which is designed to prevent the spread of fire from one compartment to another where services penetrate separating walls and floors.

Abesco Fire Rated Mortar consists of a specially blended powder which is supplied in easy to handle paper sacks. When mixed with water, Abesco Fire Rated Mortar forms a trowelable or pourable mixture which is easy to install and has excellent workability characteristics.

Why use Abesco Fire Rated Mortar ?

  • Manufactured to ISO 9001:2000
  • Suitable for large or small irregular openings
  • Easy to use
  • Simple to retro-fit additional services

Where to use Abesco Fire Rated Mortar

Abesco Fire Rated Mortar is particularly suitable

Abesco Fire Rated Mortar is particularly suitable for reinstating compartment floors where HVAC ducts, pipes and electrical services have been installed. Small holes and imperfections of fit can easily be "made good" using Abesco Fire Rated Mortar.

Typical buildings where Abesco Fire Rated Mortar is commonly used are:

  • Multi-story buildings with service risers.
  • Communication and Broadcasting Facilities.
  • Hospitals, Hotels and Apartment Blocks.
  • Power Stations and Control Rooms.

Abesco Fire Rated Mortar can be used in walls or floors.

How does Abesco Fire Rated Mortar work?

When exposed to the heat of a fire, the excellent thermal insulation properties of Abesco Fire Rated Mortar provides an effective barrier, preventing the passage of fire and smoke. Unlike sand and cement mortars or concrete, the special formulation resists shrinkage and cracking, and is not subject to spailing in a fire situation.

During installation and the curing process, Abesco Fire Rated Mortar actually expands ensuring that an excellent seal is possible even in irregular openings.

Using other Abesco Products

Other Abesco Fire Rated products can easily be used in conjunction with Abesco Fire Rated Mortar. For example, where plastic pipes are installed in a service riser with other services, Abesco Pipe Collars or Abesco Fire Wraps can be used with the Mortar to provide the required fire rating.

Fire Rated Silicone Caulk-

Abesco CP310 FR Acrylic Intumescent Caulk is a single part water based acrylic mastic, which provides a firm but flexible seal to joints in a variety of fire rated structures

PART # DESCRIPTION    
    FP-CP30310 CP310 Fire Rated Acrylic Intumescent Caulk, 10.5 oz. Cartridge, RED    
    FP-CP30350 CP310 Fire Rated Acrylic Intumescent Caulk, 10.5 oz. Cartridge, WHITE    

What happens in a Fire Situation?

When exposed to the heat of a fire, the intumescent material contained in the Intumescent Caulk expands to fill any small gaps, thereby maintaining the integrity of the seal and preventing the spread of fire from one compartment to another.

Abesco CP310 FR Acrylic Intumescent Caulk is designed to prevent the spread of fire from one compartment to another wherever services penetrate separating walls and floors, or wherever a gap remains between elements in fire rated constructions, walls or floors.

Abesco CP310 FR Acrylic Intumescent Caulk is a single part water based acrylic mastic, which provides a firm but flexible seal to joints in a variety of fire rated structures. It will not support combustion, and when exposed to fire it forms a carbonaceous char which expands to effectively seal any gaps, preventing the spread of smoke and fire through any joints.

Abesco CP310 FR Acrylic Intumescent Caulk is supplied in a range of packaging sizes.

Abesco CP310 FR Acrylic Intumescent Caulk is designed to seal and prevent the spread of fire from one compartment to another wherever cables, wires, or other services pass through firewalls and/or floors, or wherever there is a gap between elements in fire rated walls or floors

PART # DESCRIPTION PACKAGE COLOR SHIPPING WEIGHT PRICE
FP-CP30310 CP310 Fire Rated Acrylic Intumescent Caulk, 10.5 oz. Cartridge, RED 10.5 oz. Cartridge RED 1.5 lbs $10.77
FP-CP30350 CP310 Fire Rated Acrylic Intumescent Caulk, 10.5 oz. Cartridge, WHITE 10.5 oz. Cartridge WHITE 1.5 lbs $10.77

Where to use CP310 FR Acrylic Intumescent Caulk

Abesco CP310 FR Acrylic Intumescent Caulk is suitable for use in most buildings which have gaps or joints in, or where services pass through, fire rated compartment walls and floors.

Typical types of building where Abesco FR Acrylic Intumescent Mastic is commonly used are:

FlPlenum Innerduct and apartment blocks, Hotels, Prisons, Office blocks, Hospitals, Airports, Retail centres, Industrial Buildings, Plant Rooms, etc.

Abesco CP310 FR Acrylic Intumescent Caulk can be used in walls or floors. What's special about this intumescent caulk?

  • Fast cure, tack free in 75 minutes
  • Excellent adhesion to most building substrates
  • Very easy to use, install and finish
  • Excellent slump resistance
  • Tested in accordance with ASTM E814, UL1479 UL Classified 1 and 2 hour rating

Abesco CP310 FR Acrylic Intumescent Caulk is a single part water based acrylic caulk. The intumescent caulk provides a firm but flexible seal to joints in a variety of fire rated structures. The caulk will not support combustion, and, when exposed to fire it will form a carbonaceous char which expands to effectively seal any small gaps and prevent the spread of smoke and fire.

Abesco CP310 FR Acrylic Intumescent Caulk is suitable for use in any buildings which have electrical cables, metallic pipes and air conditioning ducts, etc. which penetrate through fire rated compartment walls (drywall included) and floors. Suitable for use around copper and steel pipes, steel conduits, electrical cables, data and telephone cables, PVC and CPVC pipes (up to 2" diameter), and HVAC ducts. For complete installation details, please refer to Technical Data Sheet.

  • Halogen free
  • Cost effective solution for a wide range of applications
Physical State Paste (White or Red)
Flash Point >100° C [210° F]
Boiling Point N/A
Viscosity N/A
Specific Gravity 1.62 - 1.66 @ 200° C
Vapor Pressure N/A
Vapor Density (Air=1) N/A
Solubility in water Miscible when wet
pH 8.4-9.2

Abesco FP200 FR Expanding Foam is a single pack Fire Rated polyurethane expanding foam, and is designed to prevent the spread of fire and smoke from one compartment to another through gaps and voids through fire rated walls or floors.Abesco FP200 Fire Rated Expanding Foam is an expanding, fire-rated polyurethane foam designed to prevent room-to-room fire and smoke spread through gaps or voids in fire-rated walls and floors.. FP200 Fire Rated Expanding Foam provides an insulating seal on and between concrete, brick, wood, metal, aluminum and steel

Price $ 24.95 per can, Case Price $ 23.45 Per Can

What's special about this intumescent caulk?

  • Fast cure, tack free in 75 minutes
  • Excellent adhesion to most building substrates
  • Very easy to use, install and finish
  • Excellent slump resistance
  • Tested in accordance with ASTM E814, UL1479 UL Classified 1 and 2 hour rating

Plenum Innerduct is a national Firestop distributor and firestop supplier for a multitude of firestop products and carries a complete line of Firestop Products and Fire Stop Protection products. Our complete line of firestop fire protection products helps stop the spread of fire, smoke and toxic fumes. Our firestop fire protection produsts are easy to install and are approved for a wide variety of firestop applications by Underwriter’s Laboratories. Total passive firestop and 'fire' protection cannot be achieved with the use of a singular product. It is the use of many products designed for specific firestop applications that comprise a complete passive firestop fire protection systems. When installed properly, these firestop products work in concert with one another to create effective barriers against the passage of flames, smoke, and superheated gases. Used is conjunction with other firestop fire protection methods, properly installed passive fire protection will save lives, protect property, and minimize business losses.

Firestop and Firestopping is an integral part of fire protection engineering in all commercial buildings and are required by law in most states to satisfy mandated laws for commercial building fire protection.  Firestop systems protect against the passage of flames, deadly gases and toxic smoke through openings that are created for penetrations, joints and gaps in fire-resistive walls, floors and floor/ceiling assemblies.  The integrity of fire-rated assemblies is restored by firestop systems.  Building codes require third-party tested systems to be installed whenever fire-rated construction is compromised by such openings. 

Telecomm cables found in a Hospital, the day before a Joint Commission Inspection. Cables were sleeved without having to be removed with our Split Sleeve & Bulkhead System.

Abesco Foam Firestop

Fire-Rated Intumescent Caulk

Fire Rated Silicone Caulk

Abesco Mortar

Abesco Putty

Abesco Fireclamp

Abesco Pipe Collar

What is meant by "active" and "passive" fire protection?

Active fire suppression includes mechanical systems such as sprinklers,  that are designed to extinguish fires after they have started.  Passive fire protection functions to contain fires within the areas in which they start, preventing loss of life by preventing the products of combustion (smoke, hot gasses and flames) from spreading throughout a building.

Why is "passive" fire protection necessary?

Fire is a dangerous enough phenomenon that redundancy in fire protection is necessary.  Having passive protection in place helps assure building occupants that there will be time to exit before gasses, fire and smoke spread throughout the building.  If  active systems fail, as they often do, then there is still a passive system in place for life safety.

It is the use of many products designed for specific firestop applications that comprise a complete passive firestop fire protection systems. When installed properly, these firestop products work in concert with one another to create effective barriers against the passage of flames, smoke, and superheated gases. Used is conjunction with other firestop fire protection methods, properly installed passive fire protection will save lives, protect property, and minimize business losses.

Joints

Construction joints must be sealed with joint systems, which will impart a fire resistance at least equal to those of the adjacent constructions so that overall fire resistance is not compromised.

Additional Information

Fire resistive joint systems are used in building construction to seal joints, and must be of the same or greater fire resistance (temperature) rating as the wall or floor containing the opening which they are designed to protect. Perimeter joint systems are most often used to seal a clearance separation between curtain walls and floors. They are designed to accommodate various movements induced

In fact, we’re one of the leading suppliers that can provide fully tested systems to firestop all of these scenarios:

From the leader in fire protection...
Our manufacturer partners have been creating innovative firestop systems for more than 25 years. Our complete line of fire protection products helps stop the spread of fire, smoke and toxic fumes. They’re easy to install and are approved for a wide variety of firestop applications including but not all: Underwriter’s Laboratories, Factory Mutual and Omega Point Laboratories. Plenum Innerduct as a distributor can provide fully tested systems to firestop all of these scenarios:

  • Structural steel
  • Emergency circuitry
  • Grease/air ducts
  • Through penetrations
  • Perimeter joints
  • Fire resistive joints

 

ABESCO FIREFOAM RATINGS:

  • Manufactured to ISO 9001:2000
  • Corrosion resistant suitable for use in aggressive environments
  • Certification for a wide range of cables Available in a range of sizes
  • Very easy to install and provides total flexibility in cable routing
  • Abesco graphite intumescent is unaffected by moisture
  • Approved worldwide and recognized by independent authorities and tested in accordance with
    • ASTM E-814 (UL 1479)
    • BS 476
    • AS 1530.4
    • BS EN 1366-3

   
 
 

Foam Firestop

 

What is firestop?

Firestop and Firestopping is an integral part of fire protection engineering.  Firestop systems protect against the passage of flames, deadly gases and toxic smoke through openings that are created for penetrations, joints and gaps in fire-resistive walls, floors and floor/ceiling assemblies.  The integrity of fire-rated assemblies is restored by firestop systems.  Building codes require third-party tested systems to be installed whenever fire-rated construction is compromised by such openings. 

Firerated Innerduct

Firestop and Firestopping is an integral part of fire protection engineering in all commercial buildings and are required by law in most states to satisfy mandated laws for commercial building fire protection.  Firestop systems protect against the passage of flames, deadly gases and toxic smoke through openings that are created for penetrations, joints and gaps in fire-resistive walls, floors and floor/ceiling assemblies.  The integrity of fire-rated assemblies is restored by firestop systems.  Building codes require third-party tested systems to be installed whenever fire-rated construction is compromised by such openings. 

Telecomm cables found in a Hospital, the day before a Joint Commission Inspection. Cables were sleeved without having to be removed with our Split Sleeve & Bulkhead System.

What is meant by "active" and "passive" fire protection?

Active fire suppression includes mechanical systems such as sprinklers,  that are designed to extinguish fires after they have started.  Passive fire protection functions to contain fires within the areas in which they start, preventing loss of life by preventing the products of combustion (smoke, hot gasses and flames) from spreading throughout a building.

Why is "passive" fire protection necessary?

Fire is a dangerous enough phenomenon that redundancy in fire protection is necessary.  Having passive protection in place helps assure building occupants that there will be time to exit before gasses, fire and smoke spread throughout the building.  If  active systems fail, as they often do, then there is still a passive system in place for life safety.

It is the use of many products designed for specific firestop applications that comprise a complete passive firestop fire protection systems. When installed properly, these firestop products work in concert with one another to create effective barriers against the passage of flames, smoke, and superheated gases. Used is conjunction with other firestop fire protection methods, properly installed passive fire protection will save lives, protect property, and minimize business losses.

Joints

Construction joints must be sealed with joint systems, which will impart a fire resistance at least equal to those of the adjacent constructions so that overall fire resistance is not compromised.

Additional Information -Applications Click Here

Fire resistive joint systems are used in building construction to seal joints, and must be of the same or greater fire resistance (temperature) rating as the wall or floor containing the opening which they are designed to protect. Perimeter joint systems are most often used to seal a clearance separation between curtain walls and floors. They are designed to accommodate various movements induced

In fact, we’re one of the leading suppliers that can provide fully tested systems to firestop all of these scenarios:

From the leader in fire protection...
Our manufacturer partners have been creating innovative firestop systems for more than 25 years. Our complete line of fire protection products helps stop the spread of fire, smoke and toxic fumes. They’re easy to install and are approved for a wide variety of firestop applications including but not all: Underwriter’s Laboratories, Factory Mutual and Omega Point Laboratories. Plenum Innerduct as a distributor can provide fully tested systems to firestop all of these scenarios:

  • Structural steel
  • Emergency circuitry
  • Grease/air ducts
  • Through penetrations
  • Perimeter joints
  • Fire resistive joints

Please Visit Our Product Links Below:

CT 120 Cable Transits- Designed for single or multiple cables-easy to install and alter cabling-use in floPlenum Innerduct & walks-including drywall

Firestop Products Data Sheets

 

 

Abesco CT120 Cable Transits are designed to prevent the spread of fire from one compartment to another where electrical, data, and communication cables penetrate through separating walls and floors.

Abesco CT120 Cable Transits consist of a square section steel sleeve, which contains the heat reactive intumescent material. The unit has an integral hinged top which provides an easy retro-fit option where cables are pre-installed. Abesco CT Mounting Plates provide a quick and easy method of installing single or multiple CT120 Cable Transits. even in drywall partitions.

WHY USE ABESCO CT120 CABLE TRANSITS ?

  • Manufactured to ISO 9001:2000
  • Corrosion resistant suitable for use in aggressive environments
  • Certification for a wide range of cables Available in a range of sizes
  • Very easy to install and provides total flexibility in cable routing
  • Abesco graphite intumescent is unaffected by moisture
  • Approved worldwide and recognized by independent authorities and tested in accordance with
    • ASTM E-814 (UL 1479)
    • BS 476
    • AS 1530.4
    • BS EN 1366-3

WHERE DO I USE ABESCO CT120 CABLE TRANSITS ?

 Abesco CT120 Cable Transits are suitable for use in any building where electrical, data, or communication cables penetrate through fire rated compartment floors and walls, including drywall.

Typical types of buildings where Abesco CT120 Cable Transits are commonly used are :

Banking and finance buildings, data processing centers, TV and media studios, apartment buildings, hotels, office buildings, hospitals, airports, retail centers etc.

WHAT HAPPENS IN A FIRE SITUATION ?

When exposed to the heat of a fire, the graphite based intumescent material contained in the Abesco CT120 Cable Transits expands rapidly to close and seal the inside of the sleeve, preventing the spread of fire from one compartment to another.

Additional Firestop Links Below:

Alliance for Fire and Smoke Containment and Control (AFSCC)

The American Institute of Architects (AIA)

American National Standards Institute (ANSI)

American Society for Testing and Materials (ASTM)

Building Officials and Code Administrators International (BOCA)

Canadian Fire Safety Association (CFSA)

Factory Mutual Research Corp (FMRC)

OTHER PRODUCTS

Abesco supply a wide range of Firestop products which provide the specifier, engineer and contractor with cost effective solutions to most passive fire protection problems experienced on todays construction projects.

We will beat any US-Based Company's Price On Firestop - CableTray or Raceway!

Raceway System Solutions- Cable Tray Systems-Cable tray-Cable trays-Cable Tray Systems-Raceway Systems- Flextray-Basket Tray

Snake Tray Cabletray-Raceway Systems Snake Loop

Call Us Today Tollfree At (866) 342-3721 or (866) 650-DATA

Or Click On The Chat Button At The Top Of The Page To Talk To One Of Our Representatives

 


 

 









Abesco Foam Firestop

Fire Rated Silicone Caulk

Abesco Mortar

Abesco Putty

 

Abesco Fireclamp

Abesco Pipe Collar