Data- Telecom Equipment
     About Us

Fire Rated Cable Transits- Cable Transits-Abesco Fire Cable Transits- Abesco Fire Rated Cable Transit Supplier- Firestop Distributor, Fire Stop Protection


NEW! Marine cable Transits- Call us at (866) 342-3721

Plenum Innerduct is a national Firestop distributor for the Abesco CT120 Cable Transit system which is a Through Penetration Firestop Device designed to allow cables to penetrate fire-rated floors and walls. The CT120 can also work with raceway systems and act as a fire rated raceway between rooms where cable transition is required. The Cable Transit is an easy to install fireseal with no requirement to cut any material. The Cable Transit firestop consist of a square steel sleeve with heat reactive graphite based intumescent material. If exposed to high temperatures of 300 degrees F, the intumescent material will rapidly expand to form a solid insulating char plug to seal and prevent the passage of fire or smoke. The Cable Transit firestop is suitable for common types of construction including concrete floors and walls, gypsum drywall assemblies, and rated wooden floor constructions- Cable Transits, Fire Rated Cable Transits, Abesco Cable Transit Supplier,Fire Rated Raceway, Abesco CT 120 Cable Transits, Firestop Distributor, FireStop Protection

  • Red color finish, 22 gauge steel, 10 inch length
  • Designed to allow cables to penetrate fire-rated floors and wall
  • Four different size widths to choose from: 2" round (50.8mm), 2.5" square (65mm), 4" square (102mm), 4" diameter round (102mm)
  • Suitable for use in concrete floors and walls, drywall, and wooden floors
  • Easy to install fire seal with no requirement to cut any material.

CT 120 Cable Transits- Designed for single or multiple cables-easy to install and alter cabling-use in floPlenum Innerduct & walks-including drywall

 

 Abesco CT 120 Cable Transit - Through Penetration Firestop Device- available In Square or Round Configurations- See Below

Square Design FP-CT31982 or FP-CT31940


Round Design FP-CT31950

Features:

  • Red color finish, 22 gauge steel, 10 inch length
    • Three different size width configurations to choose from:
      • 2.5 inch x 2.5 inch square (65mm)
      • 4 inch x 4 inch square (102mm)
      • 4 inch diameter round (102mm)
  • Easy installation saves labor cost
  • Suitable for use in concrete floors and walls, drywall, and wooden floors
  • May be joined together to form double or triple units using CT Mounting Flange Set (purchase separately)
  • Underwriters Laboratory UL Classified 1 and 2 hour rating
  • Tested in accordance with ASTM E814, UL1479, BS EN1366-3, BS 476 part 20, AS/NZ 1530

Ordering Information

PART # DIMENSIONS DESCRIPTION PRICE
2.5" Square
FP-CT31940 2.5" x 2.5" square x 10" length
(65mm square)
Cable Transit Firestop Device CT 120 -
2.5" x 2.5" square x 10" length
$89.00
CT 120 CT Mounting Flange Set
FP-CT31972 2.5" square SINGLE Mounting Flange Set
(2 pc. set for single part # FP-CT31940)
Used to mount one 2.5 inch CT120 unit
$16.99
FP-CT31974 2.5" x 5" DUPLEX Mounting Flange Set
(2 pc. set for quantity (2) part # FP-CT31940)
Used to mount two (2.5) inch CT120 units together side by side
$21.99
FP-CT31976 2.5" x 7.5" TRIPLEX Mounting Flange Set
(2 pc. set for quantity (3) part # FP-CT31940)
Used to mount three (2.5) inch CT120 units together side by side
$24.99
4" Square
FP-CT31942 4" x 4" square x 10" length
(102mm square)
Cable Transit Firestop Device CT 120 -
4" x 4" square x 10" length
$118.99
Mounting Flange Set
FP-CT31982 4" square SINGLE Mounting Flange Set
(2 pc. set for single part # FP-CT31942)
Used to mount one 4inch CT120 unit
$16.88
FP-CT31984 4" x 8" DUPLEX Mounting Flange Set
(2 pc. set for quantity (2) part # FP-CT31942)
Used to mount two (4) inch CT120 units together side by side
$21.88
FP-CT31986 4" x 12" TRIPLEX Mounting Flange Set
(2 pc. set for quantity (3) part # FP-CT31942)
Used to mount three (4) inch CT120 units together side by side
$25.88
2" Diameter
FP-CT31938 2" diameter x 10" length
(51mm diameter round)
Cable Transit Firestop Device CT 120
2" diameter x 10" length
$90.88
Mounting Flange Set
FP-CT31968 2" diameter round CT 120 Mounting Flange Set
2 pc. Set for single part # FP-CT31938
$9.88
4" Diameter
FP-CT31950 4" diameter x 10" length
(102mm diameter round)
Cable Transit Firestop Device CT 120 -
4" diameter x 10" length
$118.88
Mounting Flange Set
FP-CT31998 4" diameter round CT 120 CT Mounting Flange Set
(2 pc. set for single part # FP-CT31950)
$12.88

 

What is firestop?

Firestop and Firestopping is an integral part of fire protection engineering.  Firestop systems protect against the passage of flames, deadly gases and toxic smoke through openings that are created for penetrations, joints and gaps in fire-resistive walls, floors and floor/ceiling assemblies.  The integrity of fire-rated assemblies is restored by firestop systems.  Building codes require third-party tested systems to be installed whenever fire-rated construction is compromised by such openings. 

Firerated Innerduct

Firestop and Firestopping is an integral part of fire protection engineering in all commercial buildings and are required by law in most states to satisfy mandated laws for commercial building fire protection.  Firestop systems protect against the passage of flames, deadly gases and toxic smoke through openings that are created for penetrations, joints and gaps in fire-resistive walls, floors and floor/ceiling assemblies.  The integrity of fire-rated assemblies is restored by firestop systems.  Building codes require third-party tested systems to be installed whenever fire-rated construction is compromised by such openings. 

Telecomm cables found in a Hospital, the day before a Joint Commission Inspection. Cables were sleeved without having to be removed with our Split Sleeve & Bulkhead System.

What is meant by "active" and "passive" fire protection?

Active fire suppression includes mechanical systems such as sprinklers,  that are designed to extinguish fires after they have started.  Passive fire protection functions to contain fires within the areas in which they start, preventing loss of life by preventing the products of combustion (smoke, hot gasses and flames) from spreading throughout a building.

Why is "passive" fire protection necessary?

Fire is a dangerous enough phenomenon that redundancy in fire protection is necessary.  Having passive protection in place helps assure building occupants that there will be time to exit before gasses, fire and smoke spread throughout the building.  If  active systems fail, as they often do, then there is still a passive system in place for life safety.

It is the use of many products designed for specific firestop applications that comprise a complete passive firestop fire protection systems. When installed properly, these firestop products work in concert with one another to create effective barriers against the passage of flames, smoke, and superheated gases. Used is conjunction with other firestop fire protection methods, properly installed passive fire protection will save lives, protect property, and minimize business losses.

Joints

Construction joints must be sealed with joint systems, which will impart a fire resistance at least equal to those of the adjacent constructions so that overall fire resistance is not compromised.

Additional Information -Applications Click Here

Fire resistive joint systems are used in building construction to seal joints, and must be of the same or greater fire resistance (temperature) rating as the wall or floor containing the opening which they are designed to protect. Perimeter joint systems are most often used to seal a clearance separation between curtain walls and floors. They are designed to accommodate various movements induced

In fact, we’re one of the leading suppliers that can provide fully tested systems to firestop all of these scenarios:

From the leader in fire protection...
Our manufacturer partners have been creating innovative firestop systems for more than 25 years. Our complete line of fire protection products helps stop the spread of fire, smoke and toxic fumes. They’re easy to install and are approved for a wide variety of firestop applications including but not all: Underwriter’s Laboratories, Factory Mutual and Omega Point Laboratories. Plenum Innerduct as a distributor can provide fully tested systems to firestop all of these scenarios:

  • Structural steel
  • Emergency circuitry
  • Grease/air ducts
  • Through penetrations
  • Perimeter joints
  • Fire resistive joints

Please Visit Our Product Links Below:

Firestop Products Data Sheets Click

Call (866) 342-3721 Or Click On The Chat Button At The Top Of The Page To Talk To One Of Our Representatives

Abesco CT120 Cable Transits are designed to prevent the spread of fire from one compartment to another where electrical, data, and communication cables penetrate through separating walls and floors.

Abesco CT120 Cable Transits consist of a square section steel sleeve, which contains the heat reactive intumescent material. The unit has an integral hinged top which provides an easy retro-fit option where cables are pre-installed. Abesco CT Mounting Plates provide a quick and easy method of installing single or multiple CT120 Cable Transits. even in drywall partitions.

WHY USE ABESCO CT120 CABLE TRANSITS ?

  • Manufactured to ISO 9001:2000
  • Corrosion resistant suitable for use in aggressive environments
  • Certification for a wide range of cables Available in a range of sizes
  • Very easy to install and provides total flexibility in cable routing
  • Abesco graphite intumescent is unaffected by moisture
  • Approved worldwide and recognized by independent authorities and tested in accordance with
    • ASTM E-814 (UL 1479)
    • BS 476
    • AS 1530.4
    • BS EN 1366-3

WHERE DO I USE ABESCO CT120 CABLE TRANSITS ?

 Abesco CT120 Cable Transits are suitable for use in any building where electrical, data, or communication cables penetrate through fire rated compartment floors and walls, including drywall.

Typical types of buildings where Abesco CT120 Cable Transits are commonly used are :

Banking and finance buildings, data processing centers, TV and media studios, apartment buildings, hotels, office buildings, hospitals, airports, retail centers etc.

WHAT HAPPENS IN A FIRE SITUATION ?

When exposed to the heat of a fire, the graphite based intumescent material contained in the Abesco CT120 Cable Transits expands rapidly to close and seal the inside of the sleeve, preventing the spread of fire from one compartment to another.

Additional Firestop Links Below:

Alliance for Fire and Smoke Containment and Control (AFSCC)

The American Institute of Architects (AIA)

American National Standards Institute (ANSI)

American Society for Testing and Materials (ASTM)

Building Officials and Code Administrators International (BOCA)

Canadian Fire Safety Association (CFSA)

Factory Mutual Research Corp (FMRC)

OTHER PRODUCTS

Abesco supply a wide range of Firestop products which provide the specifier, engineer and contractor with cost effective solutions to most passive fire protection problems experienced on todays construction projects.

We will beat any US-Based Company's Price On Firestop - CableTray or Raceway!

Raceway System Solutions- Cable Tray Systems-Cable tray-Cable trays-Cable Tray Systems-Raceway Systems- Flextray-Basket Tray

Snake Tray Cabletray-Raceway Systems Snake Loop