|
DataCom Supply |
|
About Us |
|
©2012 Plenum Innerduct |
|
Raceway Systems-Cable
Management Solutions- Ladder Racks- Wholesale ladder Racks-Cable Management Solutions-
WireTrays - Distribution Racks- Raceway- Relay Racks- CableTies-Cable Management-
Cable Wraps-Finger Duct Panels
American
Data Supply carries a complete line of cable management solutions including cable
trays, wire trays, ladder racks, distribution racks, raceway and raceway systems
that can be tailored to meet your specific needs. Plenum Innerduct provides a complete line
of cable management products from several manufacturers including Cablofil,
Snaketray, Hendry, Newton, Signamax, Ortronics,
ICC Ladder Racks, Cable Manager,Homaco, ADC, Bailywick Systems, Damac, ADC, and others. We offer wholesale ladder rack options to make every
telephone closet or network bay installation neat, well organized and secure.American
Data Supply's ladder racks are are available in 3, 4, 5 6, 7 ft, 10 ft. versions, and
come in either a black powder coated or polished aluminum finish. For added cable
management, vertical cable channels can be added to standard distribution racks. Our new ladder racks come in 5 foot lengths that contracotrs have been requesting to lower shipping costs. Now we can ship several ladder racks- 5 feet or less via UPS-meaning lower shipping costs. Need Raceway Systems? -more info
-
|
|
|
|
Cablofil Raceway Systems |
Vutec-Wiremaid Raceway Systems |
SnakeTray Raceway Systems |
ICC Raceway Systems |
ICC Finger Duct- Click Here
-
Cable Management Panels
1u - 5 Ring
Cable Management Panel
PT ATS34-208000
|
1u - 6 Ring
Cable Management Panel
PT ATS34-208010 |
1u - 20 Ring
Cable Management Panel
PT ATS34-207200
|
2u - 5 Ring
Cable Management Panel
PT ATS34-207000
|
2u - 8 Ring
Cable Management Panel PT ATS34-207001 |
2u - 9 Ring
Cable Management Panel
PT ATS34-207300
|
2u - Channel
Cable Management Panel
PT ATS34-207800 |
2u - Dual Channel
Cable Management Panel
PT ATS34-208200
|
Side Mount
Cable Management Rings
(sold in pairs
PT ATS34-211200 |
Bridging Mount
Cable Management Rings
(sold in pairs)
PT ATS34-211300
|
1u Cable Management Rings
(sold in pairs)
|
Aluminum Distribution Rings |
Cable Routing Mushrooms |
Cable Mgmt Bar
ATS34-351900
|
Cable Mgmt Tiewrap Bar
ATS34-352500
|
2 x 6 Wall Stud Cable
Reel Holder 16"
ATS34-620000
|
19" Rack or Cabinet Mount
Cable Mgmt Panel
ATS34-LPG2008 |
|
|
|
|
|
|
|
|
Cable Management Racks Distribution Racks Below
Cable Management Racks- Accessories
Distribution Racks
CableTies
Raceway Systems
Vertical Rings
Rack Mount Rear Cable Management Bar
Metal Ring Panels
Metal Interbay Panels
Extended Cable Management Bracket
Clip Panels
Cable Management Ring Panels
Cable Management Panel Covers
Cable Management Interbay Panels
Cable Management Finger Duct Panels
Blank Panels
Distribution Rack-ICC CABLE MANAGEMENT RACK, BLACK, 7 FT ICCMSCMRH7 -- black (In Stock)
ICC's standard 19 inch cable management rack utilizes a hybrid steel construction, making it ideal for use with heavy data or electronic equipment. It has integral 6 inch cable channels along both sides of the rack to manage and conceal bulk cable vertically along the inside of the rack. The rack has cable tie anchor points throughout the cable channel to secure cable bundles with Velcro® cable ties. Includes 25 mounting screws
.
Cable Management Racks by Signamax
Cable Management Racks combine the features of a high quality relay rack, as well as effective cable routing and raceway facilities, all in one complete unit. All aluminum cable management rack allows for the mounting of a wide variety of 19 inch wide patch panels, hubs, switches, and related rack mount equipment. The rack is supplied with cable hangers, cable ties and generous provisions for organizing incoming cables for termination with effective patch cord management on the front. Racks are shipped with all assembly required plus an accessory pack that includes 20 cable ties, 16 cable hangers, 40 cuphead mounting screws, and grommeting for cable routing cutouts.
Standard equipments racks are designed for 19 inch rack mount equipment. Racks are constructed of aluminum and are available in a variety of standard heights. Each rack is drilled and tapped on both the front and the rear rails with 10-32 holes on EIA spacing. Standard rack finish is black. Racks are packaged knocked down for easy shipment.
Part Number |
Cable Management Rack DescriptionPricing- more Info |
1977-1032B |
Signamax Cable Management Rack, 19"W x 84"H, Black Finish, 10-32 Holes |
Cable Management Racks Pricing- more Info
Part Number |
Cable Management Rack Description |
RR-84B |
Signamax Equipment Rack, 19"W x 84"H, Black Finish, 10-32 Holes |
RR-48B |
Signamax Equipment Rack, 19"W x 48"H, Black Finish, 10-32 Holes |
RR-84 |
Signamax Equipment Rack, 19"W x 84"H, Milled Finish, 10-32 Holes |
RR-48 |
Signamax Equipment Rack, 19"W x 48"H, Milled Finish, 10-32 Holes |
___________________________________________________________________
------------------------------
Five Foot Ladder Racks-ICC Part Number: ICCMSLST05
Runway- Raceway section is designed to support horizontal cable running over-head. Constructed of heavy duty 16-gauge steel with a durable powder coated finish, it can be easily attached to all ICC racks.
Part Number: ICCMSLST10
10 ft*., Runway, 12 in. Wide
*We Have Shorter Lengths!! |
Runway- Raceway radius bend section is used to change the horizontal cable running over-head in a 90° vertical direction to route cables downward to a vertical ladder.
Part Number: ICCMSLOR90
Runway Radius Bend, 12 in. Wide |
Runway-raceway radius bend section is used to change the horizontal cable running over-head in a 90° vertical direction to support ceiling cable entry.
Part Number:ICCMSLIR90
Runway Radius Bend, 12 in. Wide |
Turn section is designed to change the horizontal cable running over-head in a 90° flat turn.
Part Number:ICCMSLFT90
Runway 90° Turn, 12 in. Wide |
|
|
|
|
Click Here for Installation Instructions and detailed pictures of Ladder Rack
Raceway Systems Available
|
|
|
|
Cablofil Raceway Systems |
Vutec-Wiremaid Raceway Systems |
SnakeTray Raceway Systems |
ICC Raceway Systems |
ICC Finger Duct- Click Here -------
------- ICC Racks- Cable Management
Horizontal Finger Duct Vertical Finger Duct
- -SnakeTray Raceways
Snake
Tray Snake
Tray
Hendry
Racks! | |
More Info Distribution
RacksClick --------Ladder
Racks Click NEW.......Cable
Wrap-CableTies.....
Cable
Ties-Cable Wrap-Cable Catch-Cable Hangers Plenum Innerduct's
cable management racks are made of rugged steel and feature a black powder coating.
All rack side rails have openings for cable routing, and provide cable tie anchors
in various locations. These racks are available in 4 and 7 foot models.
In
addition to floor mounted racks, a variety of wall mount racks and brackets are
available to fill specialized applications. To
add to the versatility of the distribution and cable management racks, Plenum Innerduct offers
a selection of shelves to support components that do not need to be rack mounted.
Cable
management panels are available to support bulk cable or patch cords horizontally
or vertically. These panels come with standard metal, or durable plastic rings.
Plastic snap-on covers can be added to the plastic panels to create a neat, well-organized
appearance. Brackets, vertical rings, and management bars round out Plenum Innerduct's Cable
Management Solution.
New
Ladder Rack Systems!
Call (866) 342-3721 Or Click On The Chat Button At The Top Of The Page To Talk To One Of Our Representatives
Wholesale
Ladder Racks, Ladder Rack Systems & Raceway Systems
|
Runway section is designed
to support horizontal cable running over-head. Constructed of heavy duty 16-gauge
steel with a durable powder coated finish, it can be easily attached to all ICC
racks. Part Number:
ICCMSLST10 10
ft*., Runway, 12 in. Wide *We
Have Shorter Lengths!! | Runway
radius bend section is used to change the horizontal cable running over-head in
a 90° vertical direction to route cables downward to a vertical ladder. Part
Number: ICCMSLOR90 Runway
Radius Bend, 12 in. Wide | Runway
radius bend section is used to change the horizontal cable running over-head in
a 90° vertical direction to support ceiling cable entry.
Part Number:ICCMSLIR90
Runway Radius Bend,
12 in. Wide | Turn
section is designed to change the horizontal cable running over-head in a 90° flat turn. Part
Number:ICCMSLFT90 Runway
90° Turn, 12 in. Wide |
|
|
|
|
Click
Here for Installation
Instructions and detailed pictures of Ladder Rack
| ITEM NUMBER | | DESCRIPTION | ICCMSLST10 | | Runway
Section, 12-inches Wide x 10-foot Length |
ICCMSLFT90 | |
90° Turn Section, 12-inches Wide, flat turn. |
ICCMSLIR90 | |
Inside Radius Bend Section, 12-inches Wide |
ICCMSLOR90 | |
Outside Radius Bend Section, 12-inches Wide |
ICCMSLAWSK | | Kit,
Wall Support, 12-inches Wide |
ICCMSLTWSK | | Kit,
Wall Support, Triangle, 12-inches Wide |
ICCMSLVWBK | | Bracket,
Vertical Wall Mount |
ICCMSLCMRK | | Kit,
Ceiling Mount and Rod (2 Threaded rods included) |
ICCMSLMFFK | | Kit,
Foot Floor Mount |
ICCMSLRRBK | | Bracket,
Ladder to Relay Rack, 12-inches Wide |
ICCMSLEBSK | | Kit,
End-to-end Butt Splice |
ICCMSLTJSK | | Kit,
Runway Section, T-Junction Splice |
ICCMSLCRPK | | Kit,
Cable Retaining Posts (includes 2 posts) |
ICCMSLCRDK | | Runway
Center Radius Drop, 12-inches Wide |
|
|
|
|
|
|
|
|
Miracel 19" Distribution Rack-Lab Rack NO 19 |
|
|
|
|
|
|
■ with fixed 19" built-in unit on the front
■ for built-in units in accordance with IEC 297 3
■ flexible assembly of the built-in units using T slots
For the installation of
■ 19" components on the front
■ equipment with maximum width of 450 mm
■ installation accessories
Jumpering compartment
■ front 123 mm
Load rating
■ 5000 N static
Tests
■ earthing according to VDE 0100 part 540
■ vibration test according to MIL-STD 810 E
Material / Finish
■ basic rack, extruded aluminium, polished
■ corner piece die-cast aluminium
■ multifunctional frames and 19" angular extrusions sheet steel, zinc-plated
Supply schedule
1 basic unit
2 19" aluminium vertical extrusions with T slot and increment slide for spring nut M5
2 multifunctional frames for cable clamping and universal assembly options
4 levelling feet (0-25 mm)
How supplied
■ assembled
Please note
For the installation of chassis runners and 19" shelves, additional 19"- are required at the rear.
Rack Suites
To create a rack suite, per connection you require a set of suite connectors BN 1.130.935.7
|
|
|
|
Miracel NO19 (Width 600mm) with T-slot profile |
Order Number |
nominal depth |
chassis depth |
installation height |
installation height |
nominal height |
weight |
|
T [mm] |
t [mm] |
h [U] |
h [mm] |
H [mm] |
[kg] |
|
600 |
435 |
23 |
1052 |
1200 |
14 |
01.135.793.3 |
37 |
1652 |
1800 |
16 |
01.135.795.3 |
41 |
1852 |
2000 |
17 |
01.135.796.3 |
46 |
2052 |
2200 |
18 |
01.135.797.3 |
700 |
435 |
23 |
1052 |
1200 |
15 |
01.135.799.3 |
37 |
1652 |
1800 |
17 |
01.135.801.3 |
41 |
1852 |
2000 |
18 |
01.135.802.3 |
|
|
|
|
|
800 |
635 |
23 |
1052 |
1200 |
16 |
01.135.817.3 |
37 |
1652 |
1800 |
18 |
01.135.819.3 |
41 |
1852 |
2000 |
19 |
01.135.820.3 |
46 |
2052 |
2200 |
20 |
01.135.821.3 |
900 |
735 |
37 |
1652 |
1800 |
19 |
01.135.842.0 |
41 |
1852 |
2000 |
20 |
01.135.843.0 |
46 |
2052 |
2200 |
21 |
01.135.844.0 |
|
|
|
|
|
|
|
|
|
|
|
|
|
Miracel 19" Distribution Rack – Network Rack NS 26 |
|
|
|
|
|
|
■ With fixed 19" installation on the front and rear for components in accordance with IEC 297-3
■ Installation of chassis runners and 19" shelves possible
■ Cable entry via bottom and top cover
■ Door opening angle, 180°
Variants
Type 1
■ single rack (with side panels)
Type 2
■ rack for rack suite (without side panels)
For the installation of
■ 19" components on the front and rear
■ equipment with maximum width of 450 mm
■ installation accessories
Jumpering compartment
■ front 123 mm
Load rating
■ 5000 N static
Degree of protection
IP 20 (upgradeble to IP 55)
Tests
■ Earthing in accordance with VDE 0100 T 540
■ IP Test in accordance with DIN 40 050 / IEC 529
■ Earthing in accordance with VDE 0100 T 540
■ IP Test in accordance with DIN 40 050 / IEC 529
Material / Finish
■ basis rack, extruded aluminium, polished
■ corner pieces, die-cast aluminium, polished
■ cover zinc-plated sheet steel, powder-coated textured
■ doors, sheet steel, ,powder-coated structure, glass infill front door, single security-glass panel, 4 mm
■ multifunctional members an 19"-extrusions sheet steel, zinc-plated
Colour
Final digit of order number .1:
■ Door trim RAL 9011 black
■ Visible surface of the cover RAL 7035 light grey
Final digit of order number .8:
■ Door trim RAL 9011 black
■ Visible surface of the cover RAL 7021 black grey
Supply schedule
Type 1
1 Basic rack 1 19" Vertical extrusions, sheet steel with mounting holes 2 Multifunctional struts for cable clamping and universal mounting options 2 Side panels with quick connectors 1 Cover with integrated cable entry 1 Front door, single, single safety glass panel, with handle and mounting for cylinder lock 1 Rear door, single, sheet steel, with handle and mounting for cylinder lock 1 Earth set, complete ( VDE 0100 ) 4 Levelling feet
Type 2
1 Basic rack 4 19" Vertical extrusions, sheet steel with mounting holes 2 Multifunctional struts for cable clamping and universal mounting options 1 Cover with integrated cable entry 1 Front door, single, single safety glass panel, with handle and mounting for cylinder lock 1 Rear door, single, sheet steel, with handle and mounting for cylinder lock 1 Earth set, complete ( VDE 0100 ) 4 Levelling feet
How supplied
■ assembled
|
|
|
|
Miracel NS26 (Width 800) |
Order Number |
type |
width |
height |
depth |
height |
installation height |
useable depth |
weight |
|
|
[mm] |
[mm] |
[mm] |
[U] |
h [mm] |
t [mm] |
[kg] |
|
with side panels |
800 |
2000 |
600 |
41 |
1900 |
365 |
108 |
01.136.274.X |
8700 |
2000 |
800 |
41 |
1900 |
565 |
116 |
01.136.280.X |
800 |
2200 |
800 |
46 |
2100 |
565 |
126 |
01.136.281.X |
800 |
2000 |
900 |
41 |
1900 |
665 |
120 |
01.136.286.X |
800 |
2200 |
900 |
46 |
2100 |
665 |
130 |
01.136.287.X |
without side panels |
800 |
2000 |
600 |
41 |
1900 |
365 |
99 |
01.136.300.X |
800 |
2000 |
800 |
41 |
1900 |
565 |
105 |
01.136.306.X |
800 |
2000 |
900 |
41 |
1900 |
665 |
115 |
01.136.312.X |
Replace X with the digit representing your colour choice
.1 = RAL 9011 / RAL 7035
■ Door trim RAL 9011 black
■ Visible surface of the cover RAL 7035 light grey
.8 = RAL 9011 / RAL 7021
■ Door trim RAL 9011 black
■ Visible surface of the cover RAL 7021 black grey |
|
Miracel 19" Distribution Rack
|
|
|
|
|
|
|
|
Miracel 19" Distribution Rack NS 19.8, single winged |
|
|
|
|
|
|
■ with fixed 19" built-in unit on the front
■ for built-in units in accordance with IEC 297 3
■ flexible assembly of the built-in units using T slots
■ cable entry via plinth and cover
■ heat loss discharge via ventilation dome
■ door opening angle 180°
Variants
Type 1
■ single rack (with side panels)
Type 2
■ rack for rack suite (without side panels)
For the installation of
■ 19" components on the front
■ equipment with maximum width of 450 mm
■ installation accessories
Jumpering compartment
■ front 123 mm
Load rating
■ 5000 N static
Degree of protection
Type 1
■ IP 40 (upgradeble to IP 55)
Tests
■ earthing according to VDE 0100 P 540
■ vibration test according to MIL-STD 810 E
■ IP test according to DIN 40 050 / IEC 529
Material / Finish
■ Basic rack, aluminium extrusion, polished
■ Corner piece, die-cast aluminium, polished
■ Covers, sheet steel, zinc passivated, powder-caoted, textured
■ Doors, sheet steel, powder-coated, textured, glass infill, front door, single safety glass panel, 4 mm
■ Multifunctional struts and 19" extrusions, sheet steel, zinc passivated
Colour
■ Door trim RAL 9011 black
■ Visible surface of the cover RAL 7035 light grey
Supply schedule
Type 1
1 Basic unit
2 19" aluminium vertical extrusion with T slot and increment slide for spring nut M5
2 Multifunctional frame for cable clamping and universal assembly options
1 Cover with ventilation dome and integrated cable entry
1 Front door, single-winged, single security glass panel, with handle and fixing for locking cylinders
1 Rear door, single-winged, sheet steel, with handle and fixing for locking cylinders
2 Side panels with quick locking
1 Plinth for cable entry on the side and rear with levelling feet (0-25 mm)
2 lateral plinth trim, closed
2 Plinth trim for front and rear, with airing vents and fixing for filter mat
1 Complete earthing test (VDE 0100)
Type 2
1 Basic unit
2 19" aluminium vertical extrusion with T slot and increment slide for spring nut M5
2 Multifunctional frame for cable clamping and universal assembly options
1 Cover with ventilation dome and integrated cable entry
1 Front door, single-winged, single security glass panel, with handle and fixing for locking cylinders
1 Rear door, single-winged, sheet steel, with handle and fixing for locking cylinders
1 Plinth for cable entry on the side and rear with levelling feet (0-25 mm)
2 Plinth trim for front and rear, with airing vents and fixing for filter mat
1 Complete earthing test (VDE 0100)
How supplied
■ assembled
Please note
For the installation of chassis runners and 19" shelves, additional 19"- are required at the rear. (in the Miracel 19" distribution rack NS 25 as standard).
Rack Suites
To create a rack series with the rack number, you require:
(n-1) racks without side panels
1 rack with side panels
In a rack suite, per connection you require a set of suite connectors BN 1.130.935.7
|
|
|
|
Miracel NS19.8 (Width 800mm) with a single-winged glass door |
Order Number |
type |
nominal depth |
chassis depth |
installation height |
|
nominal height |
weight |
|
|
T [mm] |
t [mm] |
h [U] |
h [mm] |
H [mm] |
[kg] |
|
with side panels |
600 |
435 |
23 |
1052 |
1320 |
78 |
01.135.001.1 |
37 |
1652 |
1920 |
103 |
01.135.003.1 |
41 |
1852 |
2120 |
112 |
01.135.004.1 |
46 |
2052 |
2320 |
121 |
01.135.005.1 |
800 |
635 |
23 |
1052 |
1320 |
80 |
01.135.019.1 |
37 |
1652 |
1920 |
111 |
01.135.021.1 |
41 |
1852 |
2120 |
120 |
01.135.022.1 |
46 |
2052 |
2320 |
129 |
01.135.023.1 |
without side panels |
600 |
435 |
23 |
1052 |
1320 |
70 |
01.135.007.1 |
37 |
1652 |
1920 |
95 |
01.135.009.1 |
41 |
1852 |
2120 |
103 |
01.135.010.1 |
46 |
2052 |
2320 |
112 |
01.135.011.1 |
800 |
635 |
23 |
1052 |
1320 |
73 |
01.135.025.1 |
37 |
1652 |
1920 |
101 |
01.135.027.1 |
41 |
1852 |
2120 |
109 |
01.135.028.1 |
46 |
2052 |
2320 |
118 |
01.135.029.1 |
|
|
|
|
|
|
|
|
|
|
|
|
|
Miracel 19" Distribution Rack – Network Rack NS 25 |
|
|
|
|
|
|
■ installation of chassis runners and 19" shelves possible
■ with fixed 19" built-in unit on the front and rear
■ for built-in units in accordance with IEC 297 3
■ flexible assembly of the built-in units using T slots
■ cable entry via plinth and cover
■ heat loss discharge via ventilation dome
■ door opening angle 180°
Variants
Type 1
■ single rack (with side panels)
Type 2
■ rack for rack suite (without side panels)
For the installation of
■ 19" components on the front and rear
■ equipment with maximum width of 450 mm
■ installation accessories
Jumpering compartment
■ front 123 mm
Load rating
■ 5000 N static
Degree of protection
IP 40 (upgradeble to IP 55)
Tests
■ earthing according to VDE 0100 P 540
■ vibration test according to MIL-STD 810 E
■ IP test according to DIN 40 050 / IEC 529
Material / Finish
■ basis rack, extruded aluminium, polished
■ corner pieces, die-cast aluminium, polished
■ cover zinc-plated sheet steel, powder-coated textured
■ doors, sheet steel, ,powder-coated structure, glass infill front door, single security-glass panel, 4 mm
■ multifunctional members an 19"-extrusions sheet steel, zinc-plated
Colour
Final digit of order number .1:
■ Door trim RAL 9011 black
■ Visible surface of the cover RAL 7035 light grey
Final digit of order number .8:
■ Door trim RAL 9011 black
■ Visible surface of the cover RAL 70321 black grey
Supply schedule
type 1
1 basic unit
4 19" aluminium vertical extrusions with T slot and increment slide for spring nut M5
2 multifunctional frame for cable clamping and universal assembly options
1 cover with ventilation dome and integrated cable entry
1 front door, single-winged, single security glass panel, with handle and fixing for locking cylinders
1 rear doors, sheet steel, with handle and fixing for locking cylinders
2 side panels with quick locking
1 plinth for cable entry on the side and rear with levelling feet (0-25 mm)
2 lateral plinth trim, closed
2 plinth trims for front and rear, with airing vents and fixing for filter mat
1 complete earthing test (VDE 0100)
type 2
1 basic unit
4 19" aluminium vertical extrusions with T slot and increment slide for spring nut M5
2 multifunctional frame for cable clamping and universal assembly options
1 cover with ventilation dome and integrated cable entry
1 front door, single-winged, single security glass panel, with handle and fixing for locking cylinders
1 rear doors, sheet steel, with handle and fixing for locking cylinders
1 plinth for cable entry on the side and rear with levelling feet (0-25 mm)
2 plinth trims for front and rear, with airing vents and fixing for filter mat
1 complete earthing test (VDE 0100)
How supplied
■ assembled
Please note
Rack suites
To create a rack series with the rack number n, you require:
(n-1) racks without side panels
1 rack with side panels
In a rack suite, per connection you require a set of suite connectors BN 01.130.935.7
|
|
|
|
Miracel NS25 (Width 800mm) |
Order Number |
type |
nominal depth |
chassis depth |
installation height |
nominal height |
weight |
|
|
T [mm] |
t [mm] |
h [U] |
h [mm] |
H [mm] |
[kg] |
|
with side panels |
600 |
365 |
41 |
1852 |
2120 |
112 |
01.136.044.1 |
41 |
1852 |
2120 |
112 |
01.136.044.8 |
800 |
565 |
41 |
1852 |
2120 |
120 |
01.136.050.1 |
41 |
1852 |
2120 |
120 |
01.136.050.8 |
46 |
2052 |
2320 |
130 |
01.136.051.1 |
46 |
2052 |
2320 |
130 |
01.136.051.8 |
900 |
665 |
41 |
1852 |
2120 |
124 |
01.136.056.1 |
41 |
1852 |
2120 |
124 |
01.136.056.8 |
46 |
2052 |
2320 |
134 |
01.136.057.1 |
46 |
2052 |
2320 |
134 |
01.136.057.8 |
1000 |
740 |
41 |
1852 |
2120 |
140 |
01.127.970.1 |
41 |
1852 |
2120 |
140 |
01.127.970.8 |
without side panels |
600 |
365 |
41 |
1852 |
2120 |
103 |
01.136.244.1 |
|
|
|
|
|
800 |
565 |
41 |
1852 |
2120 |
109 |
01.136.250.1 |
41 |
1852 |
2120 |
109 |
01.136.250.8 |
900 |
665 |
41 |
1852 |
2120 |
118 |
01.136.256.1 |
41 |
1852 |
2120 |
118 |
01.136.256.8 |
1000 |
740 |
41 |
1852 |
2120 |
128 |
01.127.975.1 |
41 |
1852 |
2120 |
128 |
01.127.975.8 |
|
|
Miracel 19" Network Equipment Rack NG 800
|
|
■ cable entry via plinth and cover
■ heat loss discharge via ventilation dome
■ door opening angle 180°
Variants
Type 1
■ single rack (with side panels)
Type 2
■ rack for rack suite (without side panels)
For the installation of
■ equipment with maximum width of 735 mm
■ shelves
■ installation accessories
Load rating
■ 5000 N static
Degree of protection
Type 1
■ IP 40 (upgradeble to IP 55)
Tests
■ earthing according to VDE 0100 P 540
■ vibration test according to MIL-STD 810 E
■ IP test according to DIN 40 050 / IEC 529
Material / Finish
■ basic rack, extruded aluminium, polished
■ corner pieces, die-cast aluminium, polished
■ covers zinc-plated sheet steel, powder-coated textured
■ doors, sheet steel, powder-coated structure, glass infill front door, single security-glass panel, 4 mm
■ multifunctional members and 19"-extrusions sheet steel, zinc-plated
Colour
■ Door trim RAL 9011 black
■ Visible surface of the cover RAL 7035 light grey
Supply schedule
Type 1
1 basic unit
2 multifunctional frame for cable clamping and universal assembly options
1 cover with ventilation dome and integrated cable entry
1 front door, single-winged, single security glass panel, with handle and fixing for locking cylinders
1 rear door, single-winged, sheet steel, with handle and fixing for locking cylinders
2 side panels with quick locking
1 plinth for cable entry on the side and rear with levelling feet (0-25 mm)
2 lateral plinth trim, closed
2 plinth trims for front and rear, with airing vents and fixing for filter mat
1 complete earthing test (VDE 0100)
Type 2
1 basic unit
2 multifunctional frame for cable clamping and universal assembly options
1 cover with ventilation dome and integrated cable entry
1 front door, single-winged, single security glass panel, with handle and fixing for locking cylinders
1 rear door, single-winged, sheet steel, with handle and fixing for locking cylinders
1 plinth for cable entry on the side and rear with levelling feet (0-25 mm)
2 plinth trims for front and rear, with airing vents and fixing for filter mat
1 complete earthing test (VDE 0100)
How supplied
■ assembled
Rack Suites
To create a rack series with the rack number n, you require:
(n-1) racks without side panels
1 rack with side panels
In a rack suite, per connection you require a set of suite connectors BN 01.130.935.
|
Miracel NG800 (Width 800mm) with glass door, single-winged |
Order Number |
type |
nominal depth |
height |
weight |
|
|
T [mm] |
t1 [mm] |
H [U] |
H [mm] |
h [mm] |
[kg] |
|
with side panels |
800 |
730 |
23 |
1320 |
1052 |
77 |
01.135.649.1 |
37 |
1920 |
1652 |
107 |
01.135.651.1 |
41 |
2120 |
1852 |
115 |
01.135.652.1 |
46 |
2320 |
2052 |
124 |
01.135.653.1 |
without side panels |
800 |
730 |
23 |
1320 |
1052 |
70 |
01.135.655.1 |
37 |
1920 |
1652 |
97 |
01.135.657.1 |
41 |
2120 |
1852 |
104 |
01.135.658.1 |
46 |
2320 |
2052 |
113 |
01.135.659.1 |
.
standard depths of 3, 4, 5, and 6 inches 5. standard lengths of 10, 12, 20
and 24 feet Solid Bottom cable tray is generally used for minimal heat generating
electrical or telecommunication applications with short to intermediate support
spans of 5 feet to 12 feet. 3. Trough Cable Tray provides: 1. Moderate
ventilation with added cable support frequency and with the bottom configuration
providing cable support every 4 inches. Available in metal and nonmetallic materials.
2. standard widths of 6, 12, 18, 24, 30, 36 inches 3. standard depths of 3,
4, 5, and 6 inches 4. standard lengths of 10, 12, 20 and 24 feet 5. fixed
rung spacing of 4 inch on center Trough cable tray is generally used for
moderate heat generating applications with short to intermediate support spans
of 5 feet to 12 feet. 4. Channel Cable Tray provides: 1. an economical
support for cable drops and branch cable runs from the backbone cable tray system.
2. standard widths of 3, 4, and 6 inches in metal systems and up to 8 inches in
nonmetallic systems. 3. standard depths of 1¼-1¾ inches in metal
systems and 1, 1 1/8, 1 5/" and 2 3/16 inches in nonmetallic systems
4. standard length of 10, 12, 20 and 24 feet Channel cable tray is used for
installations with limited numbers of tray cable when conduit is undesirable.
Support frequency with short to medium support spans of 5 to 10 feet.
5. Wire Mesh Cable Tray provides: 1. A job site, field adaptable support system
primarily for low voltage, telecommunication and fiber optic cables. These systems
are typically steel wire mesh, zinc plated. 2. standard widths of 2, 4, 6,
8, 12, 16, 18, 20, and 24 inches 3. standard depths of 1, 2, and 4 inches
4. standard length of about 10 feet (118") Wire Mesh tray is generally
used for telecommunication and fiber optic applications and are installed on short
support spans, 4 to 8 feet. 6. Single Rail Cable Tray provides: 1.
These aluminum systems are the fastest systems to install and provide the maximum
freedom fort cable to enter and exit the system. 2. Single hung or wall mounted
systems in single or multiple tiers. 3. Standard widths are 6, 9, 12, 18,
and 24 inches. 4. Standard depths are 3, 4, and 6 inches. 5. Standard
lengths are 10 and 12 feet. Single Rail Cable Tray is generally used for
low voltage and power cables installations where maximum cable freedom, side fill,
and speed to install are factors. What
materials / finishes are available for the various cable tray systems?
1. Steel (Min. Yield = 33KSI) (35 KSI for Stainless) 1. Plain: hot rolled
pickled and oiled steel per ASTM A569 (Commercial Quality) or A570 (Structural
Quality) 2. Pre-Galvanized: mill galvanized steel per ASTM A653 CS (Commercial)
or SS (Structural) G90 3. Hot Dip Galvanized After Fabrication: plain steel
which is hot dipped after fabrication per ASTM A123. 4. Stainless Steel: type
304 or 316L fully annealed stainless steel 2. Aluminum (Min.Yield =
23 KSI) 1. 6063-T6 or 5052-H32 alloy per ASTM B209 3. Fiber Reinforced
Plastic (FRP) 1. Polyester and Vinyl Ester resin systems available 2.
meet ASTM E-84 smoke density rating; Polyester 680, Vinyl Ester 1025 3. Class
1 Flame Rating and self-extinguishing requirements of ASTM D-635. Now
that I know what types of cable trays are available, what configurations are available?
1. Straight sections are available to route cables in a horizontal or vertical
plane. 2. Fittings are available to route cables in various directions in
either the horizontal or vertical planes. Typical examples of fittings include
elbows, tees, crosses, and risers. Each of these fittings are available in various
radii and bend angles. 3. Covers are accessories and shouldn't be in here
unless splices etc. are included. After
selecting the type of cable tray and configuration required, what support methods
are available?
1. Trapeze Support (Single or Multi-tier) 2. Hanger rod clamps, "J"
hangers 3. Center Hung Support 4. Wall Support 5. Underfloor Support
6. Pipe stanchions or other structures Each
of these support methods are preferable in different applications. For instance,
trapeze supports may be desired in an application where cables will be pulled
through the cable tray. Center hung supports, on the other hand, are generally
used when cables will be installed from the side of the cable tray. Center hung
supports are especially useful when future cable additions are desired. Wall supports
and underfloor supports are useful when ceiling structure is not available or
undesired. Outdoor installations are controlled by the structures available to
support the cable tray. Before selecting the type of cable tray, cable tray
configuration(s), and support method desired, what additional information do I
need to supply to the cable tray manufacturer for them to best understand and
satisfy my needs?
1. Where? Job site and installation considerations 1. Outdoor 1. supports
available affect the length and strength requirements 2. environmental loads,
ice, wind, snow, and possibly seismic 3. corrosion requirements affect the
materials and finishes 4. classified hazardous locations affect the cable
types acceptable 2. Indoor 1. support locations available affect the
length and strength of the system 2. industrial installation may require a
200 lb. Concentrated Load 3. commercial or institutional installation may
make system appearance, system weight, and space available important factors
4. environmental air handling area may affect cable types, cable tray material,
or cable tray type and need for covers 5. classified hazardous locations affect
the cable types acceptable
2. What? 1. Type and number of cables to support 1. NEC cable fill requirements
dictate size, width and depth, of system 2. cable support requirement may
control bottom type 3. largest bending radius of cable controls fitting radius
4. total of cable weight determines load to support 2. Future requirements
1. cable entry / exit freedom 2. design partially full or an expandable system
3. support type to allow for needs
B-Line Cable Management Racks
Manage Your Cable While Managing Your Budget.
Now, installers have access to the most feature rich cable management system in the industry...introducing Cooper B-Line's RCM+. Offering simplified cable management, a more flexible solution for all installations and a reduced total installed cost. RCM+ has all the configurations you need for your rack supported cable management requirements.
Flexibility -
Need gates on the left, but fingers on the right? No problem. How about adding doors on the back? Again, no problem! The RCM+ open system design offers countless options and solutions to deal with issues of cable access and cable routing...like those that are created by increasing demands for faster data transmission and higher cable density. The RCM+ incorporates an innovative modular unit concept with total interchangeability of parts over all units. All rearrangement and modification of the cable management system is done easily in the field. Flexibility...based on your application needs now and in the future.
Affordability -
Our RCM+ cable managers offer all the features of higher priced systems, PLUS features that aren't offered on products priced at two, three and four times as much. Also, because of the way the RCM+ is designed, you will find significant labor savings, dramatically improved cable routing and access options. All part of a system that can be tailored to almost any need.
Installability -
No matter what your requirement is, RCM+ can be installed in whatever configuration you need, on whatever standard 2-post rack you have or want. The clean, simply designed appearance blends with the widest range of architecture and environments. If you require retrofitting a cable manager to an existing rack, or if you are looking to add additional racks and accessories, RCM+ will cure all of your cable management headaches.
Features & Benefits:
360° cable routing... from anywhere, to anywhere, through anywhere.
The open back design permits cable to enter or exit the cable manager at any RMU level, resulting in more direct routing to any point on the rack or an adjacent cable manager. This means less cable density, looser bundling and faster moves, adds and changes. The advantages of the open back design are amplified by the open side feature of double-sided managers.
Efficient, lower cost cable installation.
The 1/4" accessory mounting holes spaced every 1/2 RMU extend along the entire height of the RCM+. They are an integral component of the open system design. Permitting quick attachment of a wide variety of cable management devices, they are used to support, segregate and route cables going in all directions, whether entering, leaving or passing through the manager.
Assists with data integrity by reducing cable density.
The RCM+ takes full advantage of the cable pass-through openings on the side of the new, deeper racks. The open sides created by spaced-apart mounting, allow cable to pass through the cable manager to an adjacent rack or into either cable manager through the open back.
Compatible with advancements in rack designs and rack supported components.
The RCM+ introduces a new system that consists of cable retention gates that uniquely nest under the two-piece double-hinged doors. When doors are opened, the gates provide containment, but can also be opened from either side or removed as convenience dictates.
The gates can be snapped on at any location and additional gates can be added to the system.
Fast and convenient access with dynamic cable containment.
The system used to mount plastic cable support fingers is common to all cable managers in every series. Any combination and arrangement of fingers can be installed on the mounting rails. The same universality is applied to the snap on hinges of all doors and gates. This interchangeability allows any RCM+ cable manager to be modified in the field to accommodate a broad range of applications. This also provides for adaptability to meet any future changes required.
Field modifiable features reduce future costs.
Call (866) 342-3721 Or Click On The Chat Button At The Top Of The Page To Talk To One Of Our Representatives
home
| cables | switches | Contact
Us our team | locations
|