Tempest Rated Patch Panels- Tempest Patch Panels-Tempest Patch Panel Siemon CAT7 Patch Panels meet or exceed all TEMPEST Miltary specifications- Call us at (866) 342-3721 for more information
TEMPEST is a codename referring to investigations and studies of compromising emission(CE).The US Military many times requires all telecommunications equipment meet these stnadards. Compromising emanations are defined as unintentional intelligence-bearing signals which, if intercepted and analyzed, may disclose the information transmitted, received, handled, or otherwise processed by any information-processing equipment. Tempest stands for Transient ElectroMagnetic Pulse Emanations Standard according to Certified Information Systems Security Professional training. EMP RADIATION Compromising emanations consist of electrical, mechanical, or acoustical energy intentionally or by mishap unintentionally emitted by any number of sources within equipment/systems which process national security information. This energy may relate to the original encrypted message, or information being processed, in such a way that it can lead to recovery of the plaintext. Laboratory and field tests have established that such CE can be propagated through space and along nearby conductors. The interception/propagation ranges and analysis of such emanations are affected by a variety of factors, e.g., the functional design of the information processing equipment; system/equipment installation; and, environmental conditions related to physical security and ambient noise. The term "compromising emanations" rather than "radiation" is used because the compromising signals can, and do, exist in several forms such as magnetic- and/or electric field radiation, line conduction, or acoustic emissions.
We Have Most Wholesale Patch Panels In Stock- Ready To Ship Plenum Innerduct is a distributor of CAT 7 patch panels and Siemon CAt 7 patch panels and has a 20 year CAT 7 end to end solution when using Siemon Cerified Installers and Siemon CAT 7 patch panels along with Siemon CAT7 cable and CAT7 jacks and inserts. Please check with our sales engineering department to get a complete CAT7 end to end solution. if you are going over to CAT7- you must go to to CAT7 jacks-(inserts) as well as cable. Plenum Innerduct offers a complete solution.
Plenum Innerduct also stocks hundreds of quality wholesale CAT 5e patch panels, wholesale CAT 6 patch panels, telco patch panels, USOC patch panels,Siemon patch panels,blank patch panels and CAT 6 and telco patch panels in stock including the entire line of Siemon telco patch panels. We carry a complete line of CAT 5e and CAT 6 Patch panels from most leading manufacturers-and if you don' t see it below- we can still get your patch panels as our web master is always months behind on his work! We have a full array of CAT 5e patch panels, CAT 6 patch panels in 12 port patch panels, 24 port patch panels, 48 port patch panels and more configurations. Plenum Innerduct offers quality and affordable Patch Panel Cross-Connect Solutions (CXS) to meet every requirement - from a consolidation point, to a complete telecommunications room. Our standard hinged patch panel is designed to allow for front cable access and 110 punch down, while rack mounted. We carry hinged patch panels from several manufacturers priced to meet your budget. The Siemon hinged patch panel comes equipped with a cable management interbay panel that allows the panel to fold down for punch down and then folds back into place. Includes mounting screws. All our patch panels Exceeds TIA/EIA CAT 5e standards. Includes mounting screws. Plenum Innerduct deserves the right to change or alter our price for any of our patch panels at anytime-please call for latest pricing and for specials not listed on this page. Prices subject to change without notice.Plenum Innerduct Carries many more CAT 5e patch panel and CAT 6 patch panel product and solution than listed below. Please call us with a part number or description and we will find you the best price in the USA. Plenum Innerduct is your number one choice for CAT 5e patch panels, CAT 6 Patch Panels, telco patch panels - call us and you'll experience the difference!
Click here for our Full Listing Suggested Siemon Price List - CALL FOR DISCOUNTS!!
Call (866) 342-3721 Or Click On The Chat Button At The Top Of The Page To Talk To One Of Our Representatives
The US and NATO TEMPEST standards define three levels of protection requirements:
Additional standards include:
All these documents remain classified and no published information is available about the actual emission limits and detailed measurement procedures that they define. However, some very basic TEMPEST information has not been classified information in the United States since 1995. Short excerpts from the main U.S. TEMPEST test standard, NSTISSAM TEMPEST/1-92, are now publicly available, but all the actual emanation limits and test procedures have been redacted from the published version. A redacted version of the introductory TEMPEST handbook NACSIM 5000 was publicly released in December 2000. Equally, the NATO standard SDIP-27 (before 2006 known as AMSG 720B, AMSG 788A, and AMSG 784) is still classified. The US AIR FORCE has published a few mandatory standards regarding Emission Security:
TEMPEST certificationThe information-security agencies of several NATO countries publish lists of accredited testing labs and of equipment that has passed these tests:
The United States Army also has a TEMPEST testing facility, as part of the U.S. Army Information Systems Engineering Command, at Fort Huachuca, Arizona. Similar lists and facilities exist in other NATO countries. TEMPEST certification must apply to entire systems, not just to individual components, since connecting a single unshielded component (such as a cable) to an otherwise secure system could dramatically alter the system RF characteristics. RED/BLACK separationTEMPEST standards require "RED/BLACK separation", i.e. maintaining distance or installing shielding between circuits and equipment used to handle plaintext classified or sensitive information (RED) and normal unsecured circuits and equipment (BLACK), the latter including those carrying encrypted signals. Manufacture of TEMPEST-approved equipment must be done under careful quality control to ensure that additional units are built exactly the same as the units that were tested. Changing even a single wire can invalidate the tests. One aspect of TEMPEST testing that distinguishes it from limits on spurious emissions (e.g. FCC Part 15) is a requirement of absolute minimal correlation between radiated energy or detectable emissions and any plaintext data that are being processed. Public researchIn 1985, Wim van Eck published the first unclassified technical analysis of the security risks of emanations from computer monitors. This paper caused some consternation in the security community, which had previously believed that such monitoring was a highly sophisticated attack available only to governments; van Eck successfully eavesdropped on a real system, at a range of hundreds of metres, using just $15 worth of equipment plus a television set. In consequence of this research such emanations are sometimes called "van Eck radiation", and the eavesdropping technique van Eck phreaking, although government researchers were already aware of the danger, as Bell Labs noted this vulnerability to secure TTY communications during WWII and was able to produce 75% of the plaintext being processed in a secure facility from a distance of 80 feet.[10] Additionally the NSA published Tempest Fundamentals, NSA-82-89, NACSIM 5000, National Security Agency (Classified) on February 1, 1982. In addition, the van Eck technique was successfully demonstrated to non-TEMPEST personnel in Korea during the Korean War in the 1950s. Markus Kuhn discovered several low-cost software techniques for reducing the chances that emanations from computer displays can be monitored remotely. With CRT displays and analogue video cables, filtering out high-frequency components from fonts before rendering them on a computer screen will attenuate the energy at which text characters are broadcast. With modern flat panel displays, the high-speed digital serial interface (DVI) cables from the graphics controller are a main source of compromising emanations. Adding random noise to the less significant bits of pixel values may render the emanations from flat-panel displays unintelligible to eavesdroppers but is not a secure method. Since DVI uses a certain bit code scheme for trying to transport an evenly balanced signal of 0 and 1 bits there may not be much difference between two pixel colours that differ very much in their colour or intensity. It may also be that the generated emanations may differ totally even if only the last bit of a pixel's colour is changed. The signal received by the eavesdropper does also depend on the frequency where the emanations are detected. The signal can be received on many frequencies at once and each frequency's signal differs in contrast and brightness related to a certain colour on the screen. Usually, the technique of smothering the RED signal with noise is not effective unless the power of the noise is sufficient to drive the eavesdropper's receiver into saturation and thus overwhelming the receiver input. Otherwise, the covering noise must be on the order of 200 decibels higher than the RED signal. LED indicators on computer equipment can be a source of compromising optical emanations. One such technique involves the monitoring of the lights on a network switch. Almost all network switches flash to show activity, and it is normal for the flashes to be directly taken from the data line. As such, a fast optical system can easily see the changes in the flickers from the data being transmitted down the wire. From here it is a time-consuming path to recover the data, but a computer once correctly programmed, can reveal the data packets and text in real time. Further, recent research has shown it is possible to detect the radiation corresponding to a keypress event from not only wireless (radio) keyboards, but also from traditional wired keyboards, and even from laptop keyboards. |
|
||||||||||||||||||||