SEALPIC®-F cables are designed for direct burial or duct applications where protection from moisture is required and aluminum shielding is desired. SEALPIC-F may be used aerially, but must be attached to a support strand.
Stub Cable- Transition Cable-PE 89, 25 Pair PE 89, Copper Telecom Cables,Seal Pic FSF PE 89- Transition Cables- Seal Pic FSF PE 39- Stub Cables- Direct Bury Copper Telecom Cables-Icky Pick
PE 39 Cable
Outdoor- Underground CAT 5e- CAT 6 Cable- More Info- Plenum Innerduct stocks thousands of direct bury CAT 5e cable, underground CAT 5e cable- Direct Bury CAT 6 cable-More Info
Plenum Innerduct Carries PE – 39 Communication Cable which comes in a six (6) pair cable configurations up to 2400 pairs manufactured for the purpose of direct burial systems communication applications in accordance with the National Electric Code.Conductor construction is soft drawn bare copper meeting the requirements of ASTM Specification B-3. The conductors are 22 awg solid copper.The conductors are insulated with polyethylene (PE) in distinctive colors to facilitate pair identification and are twisted into pairs with varying lays to minimize crosstalk.The interstices between the pairs are filled with an 80 C filling compound and covered with a low density, high molecular weight black polyethylene (PE).Plenum Innerduct Carries a complete line of stub cable, transition cable, andPE 89 direct bury copper telephone cables including the Seal Pic FSF PE 89 and Seal Pic FSF PE 39 cables which come in 25 pair to 200 pair PE 89 configurations. The PE 89 or Seal Pic FSF PE 89 and Seal Pic FSF PE 39 cables are used for distribution and long distance networks. The Seal Pic FSF 89 comes in 22 gauge and 24 gauge copper cable. The Seal Pic FSF 39 cables come in 19 gauge and 22 gauge coper. These cables are installed into ducts. One of our manufacturers, Hesfibel provided the majority of the recent Times Warner build out and operates on the principle of minimum error and the provision of high quality products and total customer satisfaction. Hesfibel has been awarded the TSE-ISO 9002 quality certification since 1993.
PE 39 Cable |
Type PE 39 Copper Cable |
Price |
PE 39 Cable Part #Plenum Innerduct OSPPE89-06 |
6 Pair PE 39 Cable - Cable is cut to order- 19 gauge- 6 pair PE 39 |
Call |
PE 39 Cable Part #Plenum Innerduct OSPPE89-12 |
12 Pair PE 39 Cable- Cable is cut to order-19 Gauge 12 Pair PE 39 Cable |
Call |
PE 39 Cable Part #Plenum Innerduct OSPPE89-18 |
18 Pair PE 39 Cable -Cable is cut to order-18 pair- 19 gauge 18 Pair PE 39 Cable |
Call |
PE 39 Cable Part #Plenum Innerduct OSPPE89-25 |
25 Pair PE 39 Cable -Cable is cut to order- 19 gauge 25 Pair PE 39 Cable |
Call |
PE 39 Cable Part #Plenum Innerduct OSPPE89-50 |
50 Pair PE 39 Cable .278lbs/foot Cable is cut to order |
Call |
PE 39 Cable Part #Plenum Innerduct OSPPE89-75 |
75 Pair PE 39 Cable - Cable is cut to order |
Call |
PE 39 Cable# ATSOSPPE89-100 |
100 Pair PE 39 Cable .484lbs/foot Cable is cut to order |
Call |
PE 39 Cable# ATSOSPPE89-150 |
150 Pair PE 39 Cable .484lbs/foot Cable is cut to order-19 Gauge 150 pair PE 89 Cable |
Call |
PE 39 Cable Part# OSPPE89-200 |
200 Pair .PE 39 Cable 945lbs/foot Cable is cut to order |
Call |
PE 39 Cable Part# OSPPE89-300 |
300 Pair PE 39 Cable 1.272lbs/foot Cable is cut to order |
Call |
PE 39 Cable Part# OSPPE89-400 |
400 Pair PE 39 Cable .1.66lbs/foot Cable is cut to order |
Call |
PE 39 Cable Part# OSPPE89-600 |
600 Pair PE 39 Cable 2.532lbs/foot Cable is cut to order |
Call |
PE 39 Cable Part# OSPPE89-900 |
900 Pair PE 39 Cable 3.868lbs/foot Cable is cut to order |
Call |
PE 39 Cable Part# OSPPE89-1200 |
1200 Pair PE 39 Cable 5.235lbs/foot Cable is cut to order |
Call |
PE 39 Cable Part# OSPPE89-1500 |
1500 Pair PE 39 Cable 6.215lbs/foot Cable is cut to order |
Call |
PE 39 Cable Part# OSPPE89-1800 |
1800 Pair PE 39 Cable 7.385lbs/foot Cable is cut to order |
Call |
PE 39 Cable Part# OSPPE89-2100 |
2100 Pair PE 39 Cable 5.235lbs/foot Cable is cut to order |
Call |
PE 39 Cable Part# OSPPE89-2400 |
2400 Pair PE 39 Cable 9.910lbs/foot Cable is cut to order |
Call |
Plenum Innerduct Carries PE – 39 Communication Cable which comes in a six (6) pair cable configurations up to 2400 pairs manufactured for the purpose of direct burial systems communication applications in accordance with the National Electric Code.Conductor construction is soft drawn bare copper meeting the requirements of ASTM Specification B-3. The conductors are 22 awg solid copper.The conductors are insulated with polyethylene (PE) in distinctive colors to facilitate pair identification and are twisted into pairs with varying lays to minimize crosstalk.The interstices between the pairs are filled with an 80 C filling compound and covered with a low density, high molecular weight black polyethylene (PE) Advantages: improved electrical stability, minimum maintenance costs
Shielding:
BJFA = 0.008" coated aluminum
BJFC = 0.005" copper
BJFG = 0.005" Alloy 194, gopher-resistant
(BJFG recommended for mechanical protection in gopher or severe service areas.)
Filling: The entire cable within the outer jacket is flooded with a petrolatum-polyethylene gel filling compound
Description:
PE 89 cable PE 39 Cable
Telecommunications Cables FAQs Text (see below)
What is the temperature range that outside plant cable can withstand?
For storage and operation: -45 degrees to 80 degrees Celsius
-49 degrees to 176 degrees Fahrenheit
For installation: -30 degrees to 60 degrees Celsius
-22 degrees to 140 degrees Fahrenheit
What is the bend radius of outside plant cable?
The bend radius for all Outside PIC cable is not less than 10 times the diameter (O.D.) of the cable. For example, if the cable O.D. is .52 inches, then the bend radius for that cable is not less than 5.2 inches.
What is the maximum pulling tension or tensile strength that can be placed on outside plant cable?
It is calculated based on the pair count and gauge of the conductors.
19 AWG = the maximum force is 22.1 lbs. per pair
22 AWG = the maximum force is 11.0 lbs. per pair
24 AWG = the maximum force is 6.6 lbs. per pair
26 AWG = the maximum force is 4.4 lbs. per pair
Are outside plant products Category 3 compatible?
In sample testing it was determined that our filled and air core cable meet or exceed Category 3 transmission requirements. Please note that RUS(REA) specification does not require testing to category 3 parameters.
Can outside plant cable be submersed in water?
We do not recommend submersing outside plant products in water. If a customer requires that a particular product be installed in water, please contact our Engineering department for suggestions |
Part Numbers: Please Note after ATSPE89 or ATSPE39 is the "number of copper cables"
PE 89 Cables: ATSPE89-50
PE 39 Cables: ATSPE39-50
Plenum Innerduct Carries PE – 89 Communication Cable which comes in a six (6) pair cable configurations up to 2400 pairs manufactured for the purpose of direct burial systems communication applications in accordance with the National Electric Code.Conductor construction is soft drawn bare copper meeting the requirements of ASTM Specification B-3. The conductors are 22 awg solid copper.The conductors are insulated with polyethylene (PE) in distinctive colors to facilitate pair identification and are twisted into pairs with varying lays to minimize crosstalk.The interstices between the pairs are filled with an 80 C filling compound and covered with a low density, high molecular weight black polyethylene (PE).
The assembly is then wrapped with two metal shield tapes:
A corrugated .008" thick polymer coated aluminum tape and a corrugated .006" polymer coated steel tape.
Application:
Suitable for use as direct burial communication applications where protection against water and moisture entry is a critical requirement. PE – 89 is recommended where rodent attack is possible.SEAL PIC-FSF is designed as a duct, aerial or direct burial cable in either exchange area service or trunk service. The core is filled with an 80 degree Centigrade filling compound and the sheath interfaces are flooded with a flooding compound. The polymer coating provides additional corrosion protection for the aluminum shield.
Conductor: Soft drawn bare copper (ASTM Spec. B-3). Solid (22 awg)
REA PE-89
-
CONDUCTOR: Solid annealed bare copper, sizes 19 AWG (.9mm ), 22 AWG (.64mm), and 24 AWG (.5mm).
-
INSULATION: Inner layer of foamed natural polyolefin covered by outer layer of solid colored polyolefin, color coded in accordance with standard telephone industry code.
-
TWISTED PAIRS: Individual conductors twisted into pairs with varying lays to minimize crosstalk and with specified color combinations to provide pair identification.
-
CABLE ASSEMBLY: Cables having 25 pairs or less are assembled in a single group. Cables having more than 25 pairs are assembled in units, each individually identified by color coded unit binders. The interstices between the pairs are filled with an 80 degree Centigrade filling compound.
-
CORE COVERING: Non-hygroscopic dielectric tape.
-
SHIELD: SEALPIC-FSF-Electrically continuous 0.008 in. (0.2mm) thick polymer coated, corrugated aluminum tape applied longitudinally with overlapped edges and flooded with a flooding compound.
-
JACKET: Black polyethylene.
-
IDENTIFICATION AND LENGTH MARKING: Manufacturer's identification, pair count, conductor size, and year of manufacture are surface marked on the jacket at 2ft. intervals. Sequentially numbered length markings are located at alternate 2 ft. intervals
PE 22 OSP Cable Available in strand counts from 6 to 2100, with various wire gauges. Insulated conductors are color coded to telephone industry standards. For aerial installation by attachment to a support strand and/or underground installation in a duct
P 89 Cable Avaialable in pair counts from 6 to 1800 and variouse wire gauges, Insulated conductors are color coded to telephone industry standards. Used primarily in buried and ducted environments where moisture protection is needed. Also available with armoring for increased mechanical protection.
MEETS REA SPECIFICATION PE-89, LATEST ISSUE.
*REA PE-39 available upon request.
Inner Jacket: Polyethylene (PE)
Outer Jacket: Polyethylene (PE)
Temperature: 60 C
Resistance: 17.235 OHMS PER M FEET at 68 DEG. F
Call for pricing, minimum order $500.00- Please- Plenum Innerduct offers cutting of cable-For custom cable lengths at an additional cost-
West Coast (866) 342-3721
New Southern CA Office ( 760) 471-8200
East Coast (866) 650-3282
For More Information On Any of the Products Below- Just click on the Pictures -More Information and Specifications For PE 39 and PE 89 Below
PE 89 Application:
For use in wet environments where protection from moisture is required. Approved for direct burial, duct or aerial installations when supported by a messenger.
PE 89 Conductors:
Solid soft bare annealed copper. Individual conductors are twisted into pairs with varying lay lengths to minimize crosstalk.
PE 89 Insulation:
Dual layer of foamed polyolefin and solid polyolefin.
PE 89 Filling Compound:
Cable core is filled with an extended thermoplastic rubber (ETPR) filling the interstices between the pairs and under the core tape.
PE 89 Core Wrap:
Non-hygroscopic, dielectric tape with overlap.
PE89 Shield:
Corrugated, copolymer coated, 8-mil aluminum tape longitudinally applied with overlap. The shield interfaces are flooded with an adhesive compound to provide a moisture barrier and inhibit corrosion.
PE 89 Jacket:
Black, sunlight-resistant, linear low-density polyethylene.
Additional Standards:
ANSI/ICEA S-84-608-1994 RUS 7 CFR 1755.890 (formerly REA PE-8
Stub Cable
Stub Cable- Stub Cable is factory process filled cable that is cut to customer specified lengths eliminating time-consuming cable preparation at the customer job site. The Stub Cable features a factory installed pneumatic cable "block" on one end of the cable (a variety of cable types are available; 22, 24, 26 gauge cable with pair counts from 50 to 1800 pair sizes). The cable block prevents air and/or filling compound leakage from pressurized cable plant to non-pressurized cable plant. The cable block is typically located 120 inches from one end of the cable and is sealed using state of the art blocking compounds. The cable block is small in diameter relative to the cable diameter to minimize obstructions and clearances from adjacent cable plant.
Transition cable- Transition Cable is a factory processed filled cable that is pre-cut to custom lengths. This eliminates time-consuming on-site preparation and the use of hazardous cleaning chemicals in the field. Additionally, cables can be provided with optional factory-installed connector modules and pulling eyes.