Copper Telecom Cables

PE 22- PE 22

About Us
cable, vdsl, patch

PE22- PE 22- PE 22 Cable- PE 22-Copper Telecom Cables-PE22-PE 22 Cable-50 Pair PE 22-100 Pair PE 22-Seal Pic FSF PE22- 25 Pair PE 22




Plenum Innerduct Is Your One Source For All Your Copper Cable-Data-Fiber Optic Needs

Type PE 89 Copper Cable -PE 89 Wholesale Division

PE 22 Cable is for use in aerial applications when supported by a messenger or in pressurized ducts.

Plenum Innerduct Carries a complete line of PE22, pe 22, stub cable, transition cable, and PE 22 direct bury copper telephone cables including the Seal Pic FSF PE 22 and Seal Pic FSF PE 22 cables which come in 25 pair PE 22to 2100 pair PE 22configurations. The PE 22 or Seal Pic FSF PE 22 and Seal Pic FSF PE 22cables are used for distribution and long distance networks. The Seal Pic FSF 22 comes in 22 gauge and 24 gauge copper cable. The Seal Pic FSF 39 cables come in 19 gauge and 22 gauge coper. These cables are installed into ducts.

 

PE 22 Cable

 

Catalog Number Size AWG No. of Pairs Overall Diameter Inch Net Weight Lbs/Mft
HW350 02406 24 6 0.38 54
HW350 02412 24 12 0.46 81
HW350 02425 24 25 0.53 132
HW350 02450 24 50 0.67 225
HW350 24100 24 100 0.87 401
HW350 22100 22 100 1.06 589
HW350 02206 22 6 0.46 69
HW350 02212 22 12 0.54 109
HW350 02225 22 25 0.66 184
HW350 02250 22 50 0.82 324
HW350 01906 19 6 0.54 108
HW350 01912 19 12 0.66 180
HW350 01925 19 25 0.82 325
HW350 01950 19 50 1.06 593
Application:

For use in aerial applications when supported by a messenger or in pressurized ducts.

Conductors:

Solid soft bare annealed copper. Individual conductors are twisted into pairs with varying lay lengths to minimize crosstalk.

Insulation:

Solid polyolefin

Core Wrap:

Non-hygroscopic, dielectric tape with overlap

Shield:

Corrugated, copolymer coated, 8-mil aluminum tape longitudinally applied with overlap.

Jacket:

Black, sunlight-resistant, linear low-density polyethylene.

Color Code:

Color code chart 5

Additional Standards:

ANSI/ICEA S-85-625-1996 (formerly REA PE-22

Outdoor- Underground CAT 5e- CAT 6 Cable- More Info- Plenum Innerduct stocks thousands of direct bury CAT 5e cable, underground CAT 5e cable- Direct Bury CAT 6 cable-More Info

PE 22 OSP Cable Available in strand counts from 6 to 2100, with various wire gauges. Insulated conductors are color coded to telephone industry standards. For aerial installation by attachment to a support strand and/or underground installation in a duct.

PE 22 Application:

For use in aerial applications when supported by a messenger or in pressurized ducts.

PE 22Conductors:

Solid soft bare annealed copper. Individual conductors are twisted into pairs with varying lay lengths to minimize crosstalk.

PE 22Insulation: Solid polyolefin

PE 22Core Wrap: Non-hygroscopic, dielectric tape with overlap

PE 22Shield: Corrugated, copolymer coated, 8-mil aluminum tape longitudinally applied with overlap.

PE 22 Jacket:Black, sunlight-resistant, linear low-density polyethylene.

PE 22Color Code: Color code chart 5

Additional Standards:

ANSI/ICEA S-85-625-1996 (formerly REA PE-22)

    Plenum Innerduct Part Number Description Due To Fluctuating Wholesale Oil Costs Call For Pricing
    PE22 1203 PE22 24AWG 6 pair .008 aluminum tape shield outside plant telephone cable
    PE22 1204 PE22 24AWG 12 pair .008 aluminum tape shield outside plant telephone cable
    PE22 1205 PE22 24AWG 25 pair .008 aluminum tape shield outside plant telephone cable
    PE22 1206 PE22 24AWG 50 pair .008 aluminum tape shield outside plant telephone cable
    PE22 1405 PE22 19AWGÿ 50 pair pair outside plant telephone cable
    PE22 1406 PE22 19AWGÿ 25 pair pair outside plant telephone cable
    PE38 1205 PE38 24AWG 25 pair .008 aluminum tape shield outside plant telephone cable with 1/4 messenger
    PE38 1206 PE38 24AWG 50 pair .008 aluminum tape shield outside plant telephone cable with 1/4 messenger
    PE38 1305 PE38 22AWG 25 pair .008 aluminum tape shield outside plant telephone cable with 1/4 messenger
    PE38 1306 PE38 22AWG 50 pair .008 aluminum tape shield outside plant telephone cable with 1/4 messenger
    PE39 1203 PE39 24AWG 6 pair .008 aluminum tape shield outside plant telephone cable
    PE39 1204 PE39 24AWG 12 pair .008 aluminum tape shield outside plant telephone cable
    PE39 1205 PE39 24AWG 25 pair .008 aluminum tape shield outside plant telephone cable
    PE39 1206 PE39 24AWG 50 pair .008 aluminum tape shield outside plant telephone cable
    PE39 1305 PE39 22AWG 25 pair .008 aluminum tape shield outside plant telephone cable
    PE39 1306 PE39 22AWG 50 pair .008 aluminum tape shield outside plant telephone cable
    PE39 1403 PE39 19AWGÿ 6 pair .008 aluminum tape shield outside plant telephone cable
    PE39 1404 PE39 19AWGÿ 12 pair .008 aluminum tape shield outside plant telephone cable
    PE39 1405 PE39 19AWGÿ 25 pair .008 aluminum tape shield outside plant telephone cable
    PE39 1406 PE39 19AWGÿ 50 pair .008 aluminum tape shield outside plant telephone cable
    PE89 1203 PE89 24AWG 6 pair foam skin .008 aluminum tape shield outside plant telephone cable
    PE89 1205 PE89 24AWG 25 pair foam skin .008 aluminum tape shield outside plant telephone cable
    PE89 1206 PE89 24AWG 50 pair foam skin .008 aluminum tape shield outside plant telephone cable
    PE89 1303 PE89 22AWG 6 pair foam skin .008 aluminum tape shield outside plant telephone cable
    PE89 1305 PE89 22AWG 25 pair foam skin .008 aluminum tape shield outside plant telephone cable
    PE89 1306 PE89 22AWG 50 pair foam skin .008 aluminum tape shield outside plant telephone cable

PE 89 cable

MEETS REA SPECIFICATION PE-89, LATEST ISSUE.
*REA PE-39 available upon request.

Inner Jacket: Polyethylene (PE)

Outer Jacket: Polyethylene (PE)

Temperature: 60 C

Resistance: 17.235 OHMS PER M FEET at 68 DEG. F


Call for pricing, minimum order $500.00- Please- Plenum Innerduct offers cutting of cable-For custom cable lengths at an additional cost-

Call (866) 342-3721 Or Click On The Chat Button At The Top Of The Page To Talk To One Of Our Representatives

For More Information On Any of the Products Below- Just click on the Pictures -More Information and Specifications For PE 39 and PE 89 Below

PE 89 Application:
For use in wet environments where protection from moisture is required. Approved for direct burial, duct or aerial installations when supported by a messenger.

PE 89 Conductors:
Solid soft bare annealed copper. Individual conductors are twisted into pairs with varying lay lengths to minimize crosstalk.

PE 89 Insulation:
Dual layer of foamed polyolefin and solid polyolefin.

PE 89 Filling Compound:
Cable core is filled with an extended thermoplastic rubber (ETPR) filling the interstices between the pairs and under the core tape.

PE 89 Core Wrap:
Non-hygroscopic, dielectric tape with overlap.

PE89 Shield:
Corrugated, copolymer coated, 8-mil aluminum tape longitudinally applied with overlap. The shield interfaces are flooded with an adhesive compound to provide a moisture barrier and inhibit corrosion.

PE 89 Jacket:
Black, sunlight-resistant, linear low-density polyethylene.

Additional Standards:
• ANSI/ICEA S-84-608-1994 • RUS 7 CFR 1755.890 (formerly REA PE-8

 

Stub Cable

Stub Cable- Stub Cable is factory process filled cable that is cut to customer specified lengths eliminating time-consuming cable preparation at the customer job site. The Stub Cable features a factory installed pneumatic cable "block" on one end of the cable (a variety of cable types are available; 22, 24, 26 gauge cable with pair counts from 50 to 1800 pair sizes). The cable block prevents air and/or filling compound leakage from pressurized cable plant to non-pressurized cable plant. The cable block is typically located 120 inches from one end of the cable and is sealed using state of the art blocking compounds. The cable block is small in diameter relative to the cable diameter to minimize obstructions and clearances from adjacent cable plant.

Transition cable- Transition Cable is a factory processed filled cable that is pre-cut to custom lengths. This eliminates time-consuming on-site preparation and the use of hazardous cleaning chemicals in the field. Additionally, cables can be provided with optional factory-installed connector modules and pulling eyes.



COPPER TELECOM CABLES


1. Foam Skin Insulated Conductor
2. Core wrapping
3. Inner PE jacket
4. Aluminium Foil
5. Outer PE jacket BRIEF DESCRIPTION
Annealed Copper Conductor
Foam Skin Insulation
Moisture Barrier
Double PE Sheathed
   
KPD - PAP TYPE CABLE KPDF - PAP TYPE CABLE
   
   
KPD - AP TYPE CABLE KPDF - AP TYPE CABLE
   
   
KPD - AP - A TYPE CABLE KPDF - AP - A TYPE CABLE
   
   
KPD - P TYPE CABLE KPD - V TYPE CABLE
   
KPD - P - A TYPE CABLE FSQAF-SWA-P TYPE CABLE
   
 
   
FSQAF-STA-P TYPE CABLE VD - AP TYPE CABLE
   
 
   
VD - V TYPE CABLE BPDT OUTDOOR DROP WIRE
   
 
   
VD - PAP TYPE CABLE BVIT INDOOR DROP WIRE
   
 
 
 
BVCT (JUMPER WIRE)
 

Call for pricing, min order $500.00 please

Lowest Priced Corning- Emerson-Aloca Fiber Cable-Jumpers in the USA!
Additional Links

We’re here to help you solve your business challenges and increase your ability to meet your own customers’ growing expectations from their telecommunications service providers.

Call Us Today Tollfree At (866) 342-3721 or (866) 650-DATA

Or Click On The Chat Button At The Top Of The Page To Talk To One Of Our Representatives