PE 22 Cable is for use in aerial applications when supported by a messenger or in pressurized ducts.
Plenum Innerduct Carries a complete line of PE22, pe 22, stub cable, transition cable, and PE 22 direct bury copper telephone cables including the Seal Pic FSF PE 22 and Seal Pic FSF PE 22 cables which come in 25 pair PE 22to 2100 pair PE 22configurations. The PE 22 or Seal Pic FSF PE 22 and Seal Pic FSF PE 22cables are used for distribution and long distance networks. The Seal Pic FSF 22 comes in 22 gauge and 24 gauge copper cable. The Seal Pic FSF 39 cables come in 19 gauge and 22 gauge coper. These cables are installed into ducts.
PE 22 Cable
Catalog Number
Size AWG
No. of Pairs
Overall Diameter Inch
Net Weight Lbs/Mft
HW350 02406
24
6
0.38
54
HW350 02412
24
12
0.46
81
HW350 02425
24
25
0.53
132
HW350 02450
24
50
0.67
225
HW350 24100
24
100
0.87
401
HW350 22100
22
100
1.06
589
HW350 02206
22
6
0.46
69
HW350 02212
22
12
0.54
109
HW350 02225
22
25
0.66
184
HW350 02250
22
50
0.82
324
HW350 01906
19
6
0.54
108
HW350 01912
19
12
0.66
180
HW350 01925
19
25
0.82
325
HW350 01950
19
50
1.06
593
Application:
For use in aerial applications when supported by a messenger or in pressurized ducts.
Conductors:
Solid soft bare annealed copper. Individual conductors are twisted into pairs with varying lay lengths to minimize crosstalk.
Insulation:
Solid polyolefin
Core Wrap:
Non-hygroscopic, dielectric tape with overlap
Shield:
Corrugated, copolymer coated, 8-mil aluminum tape longitudinally applied with overlap.
Jacket:
Black, sunlight-resistant, linear low-density polyethylene.
Color Code:
Color code chart 5
Additional Standards:
ANSI/ICEA S-85-625-1996 (formerly REA PE-22
Outdoor- Underground CAT 5e- CAT 6 Cable- More Info- Plenum Innerduct stocks thousands of direct bury CAT 5e cable, underground CAT 5e cable-Direct Bury CAT 6 cable-More Info
PE 22 OSP Cable Available in strand counts from 6 to 2100, with various wire gauges. Insulated conductors are color coded to telephone industry standards. For aerial installation by attachment to a support strand and/or underground installation in a duct.
PE 22 Application:
For use in aerial applications when supported by a messenger or in pressurized ducts.
PE 22Conductors:
Solid soft bare annealed copper. Individual conductors are twisted into pairs with varying lay lengths to minimize crosstalk.
PE 22Insulation: Solid polyolefin
PE 22Core Wrap: Non-hygroscopic, dielectric tape with overlap
PE 22Shield: Corrugated, copolymer coated, 8-mil aluminum tape longitudinally applied with overlap.
PE 22 Jacket:Black, sunlight-resistant, linear low-density polyethylene.
PE 22Color Code:
Color code chart 5
Additional Standards:
ANSI/ICEA S-85-625-1996 (formerly REA PE-22)
Plenum Innerduct Part Number
Description
Due To Fluctuating Wholesale Oil Costs Call For Pricing
MEETS REA SPECIFICATION PE-89, LATEST ISSUE.
*REA PE-39 available upon request.
Inner Jacket: Polyethylene (PE)
Outer Jacket: Polyethylene (PE)
Temperature: 60 C
Resistance: 17.235 OHMS PER M FEET at 68 DEG. F
Call for pricing, minimum order $500.00- Please- Plenum Innerduct
offers cutting of cable-For custom cable lengths at an
additional cost-
Call (866) 342-3721 Or Click On The Chat Button At The Top Of The Page To Talk To One Of Our Representatives
For More Information On Any of the Products Below- Just click on the Pictures -More Information and Specifications For PE 39 and PE 89 Below
PE 89 Application:
For use in wet environments where protection from moisture is required. Approved for direct burial, duct or aerial installations when supported by a messenger.
PE 89 Conductors:
Solid soft bare annealed copper. Individual conductors are twisted into pairs with varying lay lengths to minimize crosstalk.
PE 89 Insulation:
Dual layer of foamed polyolefin and solid polyolefin.
PE 89 Filling Compound:
Cable core is filled with an extended thermoplastic rubber (ETPR) filling the interstices between the pairs and under the core tape.
PE 89 Core Wrap:
Non-hygroscopic, dielectric tape with overlap.
PE89 Shield:
Corrugated, copolymer coated, 8-mil aluminum tape longitudinally applied with overlap. The shield interfaces are flooded with an adhesive compound to provide a moisture barrier and inhibit corrosion.
PE 89 Jacket:
Black, sunlight-resistant, linear low-density polyethylene.
Additional Standards:
ANSI/ICEA S-84-608-1994 RUS 7 CFR 1755.890 (formerly REA PE-8
Stub Cable
Stub Cable- Stub Cable is factory process filled cable that is cut to customer specified lengths eliminating time-consuming cable preparation at the customer job site. The Stub Cable features a factory installed pneumatic cable "block" on one end of the cable (a variety of cable types are available; 22, 24, 26 gauge cable with pair counts from 50 to 1800 pair sizes). The cable block prevents air and/or filling compound leakage from pressurized cable plant to non-pressurized cable plant. The cable block is typically located 120 inches from one end of the cable and is sealed using state of the art blocking compounds. The cable block is small in diameter relative to the cable diameter to minimize obstructions and clearances from adjacent cable plant.
Transition cable- Transition Cable is a factory processed filled cable that is pre-cut to custom lengths. This eliminates time-consuming on-site preparation and the use of hazardous cleaning chemicals in the field. Additionally, cables can be provided with optional factory-installed connector modules and pulling eyes.