Pull Boxes-Underground Vaults-OSP Pedestals-Transformer Pads-Pole Top Extension- OSP Closures-Primary Cabinets-Above Grade Enclosures
Outside
Plant Products-Pull Box- OSP Vaults-Underground
Vaults-Grade Level Enclosures-Pull Boxes-Handhole- Underground
Enclosures- OSP Enclosures
American
Data Supply, a registered CCR contracting
supply company
has teamed up with Alcoa, Highline Products, Carlon,
Commscope, and several other leading osp fiber
optic equipment manufacturers. Just click on any of the OSP fiber
optic enclosures below.Plenum Innerduct
now carries several models of OSP enclosures from Highline manufacturing
including Pull Boxes, Underground Vaults,OSP Pedestals,Transformer Pads, Pole Top Extensions, OSP Closures,Primary Cabinets,Above Grade Enclosures
for both new provisioning installations as well as rehabilitation
of existing access points.
Highline Products is proud to introduce a new line of 15”, 24” and 32” transformer pads. Our innovative, patented, design results in a product that is extremely strong and durable, yet lightweight. These products are manufactured at our ISO 9000 certified plant using compression molding tools and a specially formulated sheet molding compound.
Pull Boxes
-
10K and 20K load ratings available.
-
Loading characteristics conform to the Western Underground Committee recommended guide WUC 3.6.
-
Non-conductive.
-
Constructed of fire-retardant materials.
-
Cable entrances available or are easily cut in field.
-
Skid resistant covers.
-
Logo as required.
-
Penta or hex head bolts.
-
Other sizes available upon request.
PRODUCT FEATURES
- Constructed of fire-retardant materials.
- Skid resistant covers.
- Pulling eyes and cable racking installed upon request.
- Cable entrances available or are easily cut in field.
- Logo as required.
- Two piece covers on large size vaults.
- Penta or hex head bolts.
- 10K and 20K load ratings available.
- Loading characteristics conform to the Western Underground Committee recommended guide WUC 3.6.
- Other sizes available
Fiberglass Products
Compresson Molded- Spray Up Series- Transformer Pads
Fiberglass /Polymer Concrete
Pullboxes-Underground Vaults-Flat Pad- Barrel For Fiber Cable
Primary Cabinets
Single Phase Cabinets- Teo Phase Cabinet- Three Phase Cabinet
Pole Top Extensions
Plastic HDPE Boxes
Round Body- Rectangular Body
Highline Products is proud to introduce a new line of 15”, 24” and 32” transformer pads. Our innovative, patented, design results in a product that is extremely strong and durable, yet lightweight. These products are manufactured at our ISO 9000 certified plant using compression molding tools and a specially formulated sheet molding compound
October 26, 2004—WALTHAM, MA—Highline Products announced the completion of its development of the New Millennium single-phase box pad line. The development of an improved version of the company's compression molded products commenced three years ago. The goal was a significant reduction in the weight of the products, while still offering customers products that were 100% compliant with industry guidelines for strength, integrity and deflection over an extended life time. The result of this work is a patented design for box pads of 15", 24" and 32" heights that are 40% lighter than most products on the market. The new product line was developed in conjunction with Metis Design; a Cambridge, MA based consulting firm specializing in composite structures and our manufacturing partner, Molded Fiberglass Company.
Paul Tannenbaum, President of Highline Products, views the New Millennium product line as an extension of the high-quality products that Highline has provided to its utility customers since 1971. He said, "The box pads will be manufactured using a new family of match metal tools at Molded Fiberglass's, ISO 9000 certified plant in Ashtabula, OH. The nature of the New Millennium design allows Highline to offer an expanded number of top openings on the box pads. Thus, almost every utility will now have the opportunity to purchase compression molded parts with their consistent quality in strength, laminate structure, and external appearance at competitive prices."
In other developments, Highline completed the construction of a full family of molds for the production FRP/polymer splice boxes in sizes up 30" x 48" as well as a family of all polymer flat pads. Mr. Tannenbaum stated, "This development is consistent with Highline's overall strategy of product line expansion in order to more fully satisfy customers' needs."
Pull boxes can be used next to the Control Buildings.
for extra cable training room.
Pull Boxes can stand alone and be used by themselves with conduit for pulling cables.These are just a few examples of Pull Boxes with different cut outs, hole sizes, and configurations.
Highline can manufacture custom Pull Box layouts with customers request.
Are used in the underground distribution of power and signals. They
provide access to the buried lines and allow an area for splicing and
pulling of cable or housing of in-line equipment.
PRODUCT FEATURES
Pull Boxes
-
10K and 20K load ratings available.
-
Loading characteristics conform to the Western Underground Committee recommended guide WUC 3.6.
-
Non-conductive.
-
Constructed of fire-retardant materials.
-
Cable entrances available or are easily cut in field.
-
Skid resistant covers.
-
Logo as required.
-
Penta or hex head bolts.
-
Other sizes available upon request.
Polymer
Materials: Ring & Cover
The pull/splice box ring and cover shall be constructed of polymer concrete consisting of sand and aggregate bound together with a polymer resin. Internal reinforcement may be provided by means of steel, fiberglass, or a combination of the two. The polymer concrete material is to have the following minimum allowable properties to be accepted for use:
Ultraviolet Exposure: |
|
Tested in accordance with ASTM G-53 using an U.V.A. 340 bulb. |
|
Flammability Test: |
|
Tested in accordance with ASTM D-635. |
|
Accelerated Service: |
|
Tested in accordance with Procedure E, ASTM D-756. |
|
Water Absorption: |
|
Tested in accordance with Procedure E, ASTM D-570, Section 5,6,1, and 6.5. |
|
Impact Resistance: |
|
72 foot-pounds in accordance with ASTM D-2444 using a “C” Tup. |
|
Compressive Strength: |
|
11,000 psi tested in accordance with ASTM C-109 loaded at a rate between 28,000 lbs. to 41,000 lbs. per minute. |
|
Flexural Strength: |
|
7,500 psi tested in accordance with ASTM D-790. |
|
Tensile Strength: |
|
1,700 psi tested in accordance with ASTM C-496. |
|
Skid Resistance: |
|
0.50 coefficient of friction in accordance with ASTM C-1028. |
|
Chemical Resistance: |
|
Tested according to ASTM D-543, Section 7, Procedure 1 using the following chemicals:
Sodium Chloride |
5% |
Sulfuric Acid |
0.1N |
Hydrochloric Acid |
0.2N |
Sodium Sulfate |
0.1N |
Sodium Carbonate |
0.1N |
Sodium Hydroxide |
0.1N |
Transformer Oil Per ASTM |
D-543 |
Kerosene Per ASTM |
D-543 |
|
|
|
Fiberglass |
|
Materials: |
|
Base Thickness Tolerance ± 1/16” to 1/8” |
|
Flexural Strength |
|
17,000 – 18,000 psi |
|
Flex Modulus |
|
.59 – .65 psi x106 |
|
Tensile Strength |
|
9,100 – 10,500 psi |
|
Impact Strength (notched Izod) |
|
15 – 17 ft lbs/inch |
|
Glass Length |
|
1” random orientation |
|
Glass Fiber Orientation |
|
Non Random |
|
Resin Type |
|
Non-Isophthalic |
|
Filler |
|
Gypsum |
|
Water Absorption |
|
≤ 1% |
|
|
Design Load Requirements
The standard product line is designed and manufactured to perform under the following load rating designations:
10,400 # W.U.C. – 10,400 pound load applied over a 10” x 10” (100 square inch) area. This is in accordance with W.U.C. (Western Underground Committee recommended guide # 3.6 Non-Concrete Enclosures).
20,800 # W.U.C. – 20,800 pound load applied over a 10” x 10” (100 square inch) area. This is in accordance with most Department of Transportation specifications for products installed in their right-of-way behind the curb line.
|
|
|
Product Test Procedures
The following test methods have been used in evaluating the physical and chemical properties of the hybrid fiberglass/polymer concrete product line. |
|
Impact Properties (Izod) |
|
ASTM D 256 ASTM D 2444 |
|
Compressive Strength |
|
ASTM C 109 |
|
Tensile Strength |
|
ASTM C 190 |
|
Flexural Strength |
|
ASTM C 293 |
|
Chemical Resistance |
|
ASTM D 543 |
|
Simulated Sunlight |
|
ASTM D 1501 |
|
Vicat Softening Temperature |
|
ASTM D 1525 |
|
Water Absorption |
|
ASTM D 570 |
|
Ultra Violet Resistance |
|
ASTM G 53 |
|
Brittleness Temperature |
|
ASTM D 746 |
|
Flammability |
|
ASTM D 635 |
|
Static Coefficient of Friction |
|
ASTM C 1028 |