OTDRs-Optical
Time Domain Reflectometers
OTDR- OTDRs- Noyes Otdr- Noyes OTDRs- Gn Nettest OTDR- Nettest OTDRs- Nettest OTDR- Anritsu OTDR
Plenum Innerduct Carries the complete line of OTDR, OTDRs, including the entire line of Noyes Otdr, Noyes Otdrs, Gn Nettest OTDR, Nettest OTDRs , Nettest OTDR, Anritsu OTDR'. The Noyes M600-K-QUAD with ST-SC Multimode and Single Mode 850nm, 1300nm, 1310nm and 1550nm. The Noyes Mini-OTDR comes with a multimode ST connector port and a single mode SC connector port. Includes keyboard, 32Mb flash card memory and USB flash card PC link, trace analysis software, serial cable, carry case, removable lead-acid battery, universal AC adapter and manual.SEE THE ENTIRE LINE OF NOYES OTDR'S BELOW.
West Coast (866) 342-3721 ------ ------
West Coast Sales (866) 342-3721 East Coast Sales (866) 650-DATA
Nettest Otdr's -Nettest OTDR's
Plenum Innerduct also carries the completer line of Noyes Fiber Optic Test Equipment-including FC Noyes Backreflection Meters, SC Noyes Backreflection Meters,ST Back Relection Meters,Fiber Optic Laser Sources, Fiber Optic Light Sources, OTDR's. Mini- OTDR's, Optical Power Sources, Fiber Test Kits, Fiber Optic Scopes and Fiber Optic Laser Sources
see our entire NOYES Pricing here |
Noyes OTDR's-Optical Time Domain Relfectometers- Call Today-We Carry The Complete Line- (866) 342-3721
Noyes M600 OTDR's Noyes 100 Mini OTDR
The Noyes Noyes M600-K-SM1-FC Mini-OTDR. Includes keyboard, trace analysis software, serial cable, carry case, (1) removable lead-acid battery, universal AC adapter - specify power cord type (North American, UK, or Euro) and manual. The North American power cord is suppied unless otherwise stated. It is a full featured mini-OTDR designed to accept single mode (1310/1550 nm) fibers.Noyes M600-K-QUAD-ST-SC Mini-OTDR. Includes keyboard, trace analysis software, serial cable, carry case, (1) removable lead-acid battery, universal AC adapter - specify power cord type (North American, UK, or Euro) and manual. The North American power cord is suppied unless otherwise stated. It is a full featured mini-OTDR designed to accept single and multimode (850, 1300, 1310,1550,nm) fibers. The standard mainframe includes a 7.7 inch, color LCD display, 3.5 inch floppy disk drive, and nonvolatile memory to store up to 50 traces. Pulse width and range can be set automatically for maximum ease-of-use, or manually for maximum flexibility. Dynamic Range is 21/23/26/26 dB, Event Dead Zone is 5M. and the Attenuation Dead Zone is 15M. The Noyes M100-K-QUAD Micro OTDR caomes with Multimode and Single Mode 850nm, 1300nm, 1310nm and 1550nm Micro-OTDR. Includes built-in VFI, keyboard, 32Mb flash card memory and USB flash card PC link, trace analysis software, serial cable, carry case, AC adapter, manual, plus switchable SC, FC and ST adapters
OFL 200 Handheld OTDR- Part Number ATS-OFL-200
The OFL 200 OTDR sets new standards for size, weight, ease-of-use, and value in a telco/broadband OTDR. Smaller than many optical loss test sets, the OFL 200 has the range, features, and price to make it the perfect OTDR for outside plant crews installing and maintaining optical fiber cables in broadband, metro, access, and FTTH networks.
Unlike ‘optical fault locators’, which detect only reflective events, the OFL 200 is a true OTDR, which detects fiber backscatter as well as fresnel reflections. Thus, the OFL 200 can locate reflective and non-reflective breaks, including those caused by crushed fibers. In addition, the OFL 200 provides an integrated 650 nm visual fault locator (VFL) for short-distance troubleshooting and fiber tracing.
In its [Full Auto] mode, the OFL 200 measures fiber length and sets range, pulse width, and averaging time automatically. [Full Auto] mode is ideal for operators not familiar with OTDRs. [Semi Auto] mode allows the user to set range while the OFL 200 sets all other parameters. [Manual] mode is available for experienced users. [Live] mode is provided for first connector checking and troubleshooting.
The fast change switchable adapter allows the OTDR to interface launch cables with a variety of connector styles. The OFL 200 can internally store up to 48 traces. Using the supplied serial cable, saved traces can be transferred to a PC for archiving, printing, and analyzing with the supplied Trace600 Windows® software. Test results are stored in Bellcore [*.sor] GR-196 Version 1.1 format.
Features:
- Rugged, handheld, lightweight
- Designed for field use
- 1550 nm single-mode OTDR
- > 70 km effective range
- Locates reflective and non-reflective breaks
- Built-in 650 nm visual fault locator (VFL) with universal adapter
- Switchable OTDR port adapter
- Cursor and zoom controls to measure event loss, reflectance, and location
- Automatic, semi-automatic, and manual setup modes
- Launch level connection quality indicator
- Large LCD with Backlight
- Free Windows® compatible software to view, print, and archive test records
- Rechargeable NiMH battery pack, AC adapter, or AA alkaline
- Wide temperature range: -10 to + 50°C
Noyes-M100 Handheld OTDR, AFL M100 OTDR- Plenum Innerduct Part Number ATSM100
The new Noyes M100 OTDR is the world's first handheld, single-mode and multimode, four-wavelength Optical Time Domain Reflectometer with integrated VFL (visual fault locator). Using "PDA" technology the M100 reaches a new level of value and portability. By combining a simple user interface with the features of a mini-OTDR in a "micro" package, the M100 is ideal for premises network Tier 2 fiber link certification and fault-location measurements including: connection loss and reflectance, splice loss, and fiber loss slope (attenuation rate). The M100 is also suited for broadband service providers looking for a highly portable OTDR to document and trouble-shoot fiber links in their access and FTTx (fiber to the home/curb/office) networks.
Both the multimode and single-mode OTDR ports are equipped with tool-free, switchable adapter mounts. ST, SC, and FC adapters are provided. The VFL port is equipped with a universal adapter that accepts any standard 2.5 mm connector. Saved test results can be transferred to a PC for archiving, printing, and analyzing with the supplied trace analysis software. Test results are stored in [*.sor] format.
All M100 models include: CompactFlash™ memory card, trace analysis software, carry case, AC adapter (specify power cord), manual, plus switchable SC, FC, and ST adapters.
Features:
-
Hand-held size and < 2.7 lb (1.2 kg)
-
850/1300/1310/1550 nm
-
Integrated Visual Fault Locator (650 nm)
-
Tool-free, switchable adapters (ST/SC/FC)
-
Bellcore (GR-196) file format
-
Compact Flash™ memory card
-
Trace600 PC software for trace analysis and printing
-
Active-matrix color display
Applications:
-
Premises network "Tier 2" certification
-
Broadband/access network testing
-
Baseline tracing
-
Fault-location
-
Connection loss and reflectance
-
Splice verification
-
Noyes OFL 100 Accessories:
Model Description
M100-00-0108 CompactFlash Card Holder
M100-00-0107 M100 battery pack
2900-50-0002 FC adapter
2900-50-0003 SC adapter
2900-50-0004 ST adapter
2900-50-0006 LC adapter
Please specify power cord type (country) when ordering an AC Adapter. One power cord is included with each AC Adapter. Additional power cords may be purchased separately.
Model Country Description
6000-12-0001 USA 2 COND, IEC 320-C7
6000-12-0002 EURO 2 COND, 7.5 AMP, IEC 320-C7 TYPE B
6000-12-0003 UK 2 COND, IEC 320-C7 TYPE D
6000-12-0004 AUSTRALIA 2 COND, IEC-320-C7 TYPE C
6000-12-0005 INDIA 2 COND, IEC-320-C7 TYPE G
6000-12-0006 JAPAN 2 COND, IEC-320-C7 TYPE M
OTDR Fiber Rings and Fiber Boxes
OTDRs require launch and receive test cables to measure the end-to-end loss of optical fiber links. A launch cable, which connects the OTDR to the link under test, reveals the insertion loss and reflectance of the near-end connection. A receive cable, which is connected to the far-end of the link, reveals the insertion loss and reflectance of the far-end connection.
Noyes OTDR test cables are available in two forms. Fiber Rings, which provide 150m of 50µm, 62.5µm, or single-mode fiber in a compact, light-weight ring, are ideal for testing optical fiber links (up to about 2 km) in premises networks. Fiber Boxes, which are available in standard lengths up to 1 km, are ideal for testing single-mode fiber spans (up to 50 km or longer) in Telco and Broadband networks. Please call or email for information about other length OTDR fiber boxes and Network Simulators, which are fiber boxes with customer-specified splices, connections, or other events.
Features:
- Available multimode and single-mode
- New configurations include rings for MT-RJ testing
- Compact, rugged cases
Fiber Rings (FR)
Model Fiber Type
FR1-M5-150-x1-x2 Multimode, 50 µm
Standard, one fiber 150 m (492 ft)
FR1-M6-150-x1-x2 Multimode, 62.5 µm
Standard, one fiber 150 m (492 ft)
FR1-SM-150-y1-y2 Single-mode,
Standard, one fiber 150 m (492 ft)
FR3-M5-x1-MTRJ Multimode, 50 µm
MT-RJ, two fibers 150 m (492 ft)
FR3-M6-x1-MTRJ Multimode, 62.5 µm
MT-RJ, two fibers 150 m (492 ft)
FR3-SM-x1-MTRJ Single-mode
MT-RJ, two fibers 150 m (492 ft)
F4-M5-MTRJ Multimode, 50 µm
MT-RJ, one fiber, loop-back 150 m (492 ft)
FR4-M6-MTRJ Multimode, 62.5 µm
MT-RJ, one fiber, loop-back 150 m (492 ft)
FR4-SM-MTRJ Single-mode
MT-RJ, one fiber, loop-back 150 m (492 ft)
Fiber Boxes (FB)
FB1-SM-500-y1-y2 Single-mode, SMF-28
Standard, one fiber 500 m (1640 ft)
FB1-SM-1000-y1-y2 Single-mode, SMF-28
Standard, one fiber 1000 m (3281 ft)
x1, x2 - connectors for multimode cables, specify type
(e.g. ST, SC)
y1, y2 - connectors for single-mode cables, specify type
(e.g. ST, SC, FC)
Other connector types, fiber types, and fiber lengths will be quoted upon request
Part Number-Description Call Plenum Innerduct Today At (866) FIBER-21 For Discounts
M600-K-SM1-FC Noyes Single Mode Mini-OTDR (FC)
M600-K-SM1-SC Noyes Single Mode Mini-OTDR (SC)
M600-K-SM1-ST Noyes Single Mode Mini-OTDR (ST)
M600-K-QUAD-ST-SC Noyes Single Mode and Multimode Mini OTDR (ST/SC)
M600-K-QUAD-ST-ST Noyes Single Mode and Multimode Mini OTDR (ST/ST)
M600-K-QUAD-FC-SC Noyes Single Mode and Multimode Mini OTDR (FC/SC)
M600-K-QUAD-FC-ST Noyes Single Mode and Multimode Mini OTDR (FC/ST)
M600-K-QUAD-SC-FC Noyes Single Mode and Multimode Mini OTDR (SC/FC)
M600-K-QUAD-SC-SC Noyes Single Mode and Multimode Mini OTDR (SC/SC)
M600-K-QUAD-SC-ST Noyes Single Mode and Multimode Mini OTDR (SC/ST)
M600-K-QUAD-ST-FC Noyes Single Mode and Multimode Mini OTDR (ST/FC)
M600-K-QUAD-FC-FC Noyes Single Mode and Multimode Mini OTDR (FC/FC)
M100-K-QUAD Noyes Single Mode and Multimode Micro OTDR
M600-K-MM1-SC Noyes Multimode Mini-OTDR (SC)
M600-K-MM1-ST Noyes Multimode Mini-OTDR (ST)
Noyes M600-K-SM1-FC Mini-OTDR. Includes keyboard, trace analysis software, serial cable, carry case, (1) removable lead-acid battery, universal AC adapter - specify power cord type (North American, UK, or Euro) and manual. The North American power cord is suppied unless otherwise stated. It is a full featured mini-OTDR designed to accept single mode (1310/1550 nm) fibers. The standard mainframe includes a 7.7 inch, color LCD display, 3.5 inch floppy disk drive, and nonvolatile memory to store up to 50 traces. Pulse width and range can be set automatically for maximum ease-of-use, or manually for maximum flexibility. Dynamic Range is 26/26 dB, Event Dead Zone is 5M. and the Attenuation Dead Zone is 15M.
Noyes M600-K-SM1-SC Mini-OTDR. Includes keyboard, trace analysis software, serial cable, carry case, (1) removable lead-acid battery, universal AC adapter - specify power cord type (North American, UK, or Euro) and manual. The North American power cord is suppied unless otherwise stated. It is a full featured mini-OTDR designed to accept single mode(1310/1550 nm) fibers. The standard mainframe includes a 7.7 inch, color LCD display, 3.5 inch floppy disk drive, and nonvolatile memory to store up to 50 traces. Pulse width and range can be set automatically for maximum ease-of-use, or manually for maximum flexibility. Dynamic Range is 26/26 dB, Event Dead Zone is 5M. and the Attenuation Dead Zone is 15M.
Noyes M600-K-SM1-ST Mini-OTDR. Includes keyboard, trace analysis software, serial cable, carry case, (1) removable lead-acid battery, universal AC adapter - specify power cord type (North American, UK, or Euro) and manual. The North American power cord is suppied unless otherwise stated. It is a full featured mini-OTDR designed to accept single mode (1310/1550 nm) fibers. The standard mainframe includes a 7.7 inch, color LCD display, 3.5 inch floppy disk drive, and nonvolatile memory to store up to 50 traces. Pulse width and range can be set automatically for maximum ease-of-use, or manually for maximum flexibility. Dynamic Range is 26/26 dB, Event Dead Zone is 5M. and the Attenuation Dead Zone is 15M.
Noyes M600-K-QUAD-ST-SC Mini-OTDR. Includes keyboard, trace analysis software, serial cable, carry case, (1) removable lead-acid battery, universal AC adapter - specify power cord type (North American, UK, or Euro) and manual. The North American power cord is suppied unless otherwise stated. It is a full featured mini-OTDR designed to accept single and multimode (850, 1300, 1310,1550,nm) fibers. The standard mainframe includes a 7.7 inch, color LCD display, 3.5 inch floppy disk drive, and nonvolatile memory to store up to 50 traces. Pulse width and range can be set automatically for maximum ease-of-use, or manually for maximum flexibility. Dynamic Range is 21/23/26/26 dB, Event Dead Zone is 5M. and the Attenuation Dead Zone is 15M.
Noyes M600-K-QUAD-ST-ST Mini-OTDR. Includes keyboard, trace analysis software, serial cable, carry case, (1) removable lead-acid battery, universal AC adapter - specify power cord type (North American, UK, or Euro) and manual. The North American power cord is suppied unless otherwise stated. It is a full featured mini-OTDR designed to accept single and multimode (850, 1300, 1310,1550,nm) fibers. The standard mainframe includes a 7.7 inch, color LCD display, 3.5 inch floppy disk drive, and nonvolatile memory to store up to 50 traces. Pulse width and range can be set automatically for maximum ease-of-use, or manually for maximum flexibility. Dynamic Range is 21/23/26/26 dB, Event Dead Zone is 5M. and the Attenuation Dead Zone is 15M.
Noyes M600-K-QUAD-SC-FC Mini-OTDR. Includes keyboard, trace analysis software, serial cable, carry case, (1) removable lead-acid battery, universal AC adapter - specify power cord type (North American, UK, or Euro) and manual. The North American power cord is suppied unless otherwise stated. It is a full featured mini-OTDR designed to accept single and multimode (850, 1300, 1310,1550,nm) fibers. The standard mainframe includes a 7.7 inch, color LCD display, 3.5 inch floppy disk drive, and nonvolatile memory to store up to 50 traces. Pulse width and range can be set automatically for maximum ease-of-use, or manually for maximum flexibility. Dynamic Range is 21/23/26/26 dB, Event Dead Zone is 5M. and the Attenuation Dead Zone is 15M.
Noyes M600-K-QUAD-SC-FC Mini-OTDR. Includes keyboard, trace analysis software, serial cable, carry case, (1) removable lead-acid battery, universal AC adapter - specify power cord type (North American, UK, or Euro) and manual. The North American power cord is suppied unless otherwise stated. It is a full featured mini-OTDR designed to accept single and multimode (850, 1300, 1310,1550,nm) fibers. The standard mainframe includes a 7.7 inch, color LCD display, 3.5 inch floppy disk drive, and nonvolatile memory to store up to 50 traces. Pulse width and range can be set automatically for maximum ease-of-use, or manually for maximum flexibility. Dynamic Range is 21/23/26/26 dB, Event Dead Zone is 5M. and the Attenuation Dead Zone is 15M. |
Noyes M600-K-QUAD-SC-SC- Mini-OTDR. Includes keyboard, trace analysis software, serial cable, carry case, (1) removable lead-acid battery, universal AC adapter - specify power cord type (North American, UK, or Euro) and manual. The North American power cord is suppied unless otherwise stated. It is a full featured mini-OTDR designed to accept single and multimode (850, 1300, 1310,1550,nm) fibers. The standard mainframe includes a 7.7 inch, color LCD display, 3.5 inch floppy disk drive, and nonvolatile memory to store up to 50 traces. Pulse width and range can be set automatically for maximum ease-of-use, or manually for maximum flexibility. Dynamic Range is 21/23/26/26 dB, Event Dead Zone is 5M. and the Attenuation Dead Zone is 15M.
Noyes M600-K-QUAD-ST-FC Mini-OTDR. Includes keyboard, trace analysis software, serial cable, carry case, (1) removable lead-acid battery, universal AC adapter - specify power cord type (North American, UK, or Euro) and manual. The North American power cord is suppied unless otherwise stated. It is a full featured mini-OTDR designed to accept single and multimode (850, 1300, 1310,1550,nm) fibers. The standard mainframe includes a 7.7 inch, color LCD display, 3.5 inch floppy disk drive, and nonvolatile memory to store up to 50 traces. Pulse width and range can be set automatically for maximum ease-of-use, or manually for maximum flexibility. Dynamic Range is 21/23/26/26 dB, Event Dead Zone is 5M. and the Attenuation Dead Zone is 15M.
Noyes M600-K-QUAD-FC-FC Mini-OTDR. Includes keyboard, trace analysis software, serial cable, carry case, (1) removable lead-acid battery, universal AC adapter - specify power cord type (North American, UK, or Euro) and manual. The North American power cord is suppied unless otherwise stated. It is a full featured mini-OTDR designed to accept single and multimode (850, 1300, 1310,1550,nm) fibers. The standard mainframe includes a 7.7 inch, color LCD display, 3.5 inch floppy disk drive, and nonvolatile memory to store up to 50 traces. Pulse width and range can be set automatically for maximum ease-of-use, or manually for maximum flexibility. Dynamic Range is 21/23/26/26 dB, Event Dead Zone is 5M. and the Attenuation Dead Zone is 15M.
Noyes M600-K-QUAD-FC-SC Mini-OTDR. Includes keyboard, trace analysis software, serial cable, carry case, (1) removable lead-acid battery, universal AC adapter - specify power cord type (North American, UK, or Euro) and manual. The North American power cord is suppied unless otherwise stated. It is a full featured mini-OTDR designed to accept single and multimode (850, 1300, 1310,1550,nm) fibers. The standard mainframe includes a 7.7 inch, color LCD display, 3.5 inch floppy disk drive, and nonvolatile memory to store up to 50 traces. Pulse width and range can be set automatically for maximum ease-of-use, or manually for maximum flexibility. Dynamic Range is 21/23/26/26 dB, Event Dead Zone is 5M. and the Attenuation Dead Zone is 15M.
Noyes M100-K-QUAD Multimode and Single Mode 850nm, 1300nm, 1310nm and 1550nm Micro-OTDR. Includes built-in VFI, 32Mb flash card memory and USB flash card PC link, trace analysis software, serial cable, carry case, AC adapter, manual, plus switchable SC, FC and ST adapters
Noyes M600-K-MM1-SC Mini-OTDR. Includes keyboard, trace analysis software, serial cable, carry case, (1) removable lead-acid battery, universal AC adapter - specify power cord type (North American, UK, or Euro) and manual. The North American power cord is suppied unless otherwise stated. It is a full featured mini-OTDR designed to accept multimode (850/1300 nm) fibers. The standard mainframe includes a 7.7 inch, color LCD display, 3.5 inch floppy disk drive, and nonvolatile memory to store up to 50 traces. Pulse width and range can be set automatically for maximum ease-of-use, or manually for maximum flexibility. Dynamic Range is 21/23 dB, Event Dead Zone is 5M. and the Attenuation Dead Zone is 15M.
Noyes M600-K-MM1-ST Mini-OTDR. Includes keyboard, trace analysis software, serial cable, carry case, (1) removable lead-acid battery, universal AC adapter - specify power cord type (North American, UK, or Euro) and manual. The North American power cord is suppied unless otherwise stated. It is a full featured mini-OTDR designed to accept multimode (850/1300 nm) fibers. The standard mainframe includes a 7.7 inch, color LCD display, 3.5 inch floppy disk drive, and nonvolatile memory to store up to 50 traces. Pulse width and range can be set automatically for maximum ease-of-use, or manually for maximum flexibility. Dynamic Range is 21/23 dB, Event Dead Zone is 5M. and the Attenuation Dead Zone is 15M.
click here to go back to our fiber test page
Plenum Innerduct Carries A Full Line Of Fiber Optic Test Equipment Products from several leading manufacturers. We have a complete line of Power Meters, Light Sources,OTDR's, Test Kits, Optical Power Meters, Inspection Scopes, and many more.
If you do not see your product listed, please call our sales office for additional information.Plenum Innerduct also carries refurbished fiber optic test equipment at greatly reduced prices. Call us for additional details.
CALL (866) FIBER -21
We carry manufacturers from Advanced Fiber Solutions,Noyes, Fluke, Seikoh Giken, Ideal, Exfo, Perkin Elmer, Ocean Optics and more. We carry a full range of OTDR's, Optical Loss Power Meters, Laser and LED Light Sources,Fiber Optic Splicing Kits, and more. We Have Hundreds Of Fiber Optic Test Equipment Products- Too Many To List Here- If It's Fiber Optic Related Test Equipment- We Have It- For LESS!!
OTDR Model Number: MW9076
Description
Plenum Innerduct Carries the new MW9076 mini-OTDR which can perform an OTDR
measurement three to five times faster than the well received, conventional OTDR-MW9070B.
Three and four-wavelength OTDRs are included among the new product lineup. The
four-wavelength OTDR can measure the chromatic dispersion characteristics from
one end of an optical fiber. Two types of color displays with high resolution
(5cm) and many sampling points (50000 points) are available for indoor and outdoor
use. The MW9076 series shows superior basic performance that enables a wide dynamic
range and a short dead zone. It supports the construction and maintenance of the
optical fiber cables. Moreover, using this OTDR, it is possible not only to quickly
charge a lithium-ion battery but also to indicate the remaining battery charge.
Features
45
dB high dynamic range
Short 8 m dead zone
Simple measurement of chromatic
dispersion from one end of an optical fiber
Measurement in 10 s (Full-Auto
mode), 0.15 s real-time sweep
5 cm high resolution, 50,000 sampling points
8.4 inch TFT-LCD color display
OTDR
Model Number: MW9070B
Description
The
MW9070B is a high-performance mini-OTDR for installation and maintenance of subscriber
fiber optic lines and other fiber optic cables. It automatically detects the positions
of faults in the cable and displays an event table listing faults and a trace
waveform. The high-performance mini-OTDR has a large 7" screen while staying
within the size of a B5 file and weighing in at only 3.2 kg.
The
MW9070B is designed with a wide dynamic range and short dead zone and is indispensable
for detecting faults in optical trunk lines, subscriber lines, optical CATV cables,
optical LANs, and other types of fiber optic cables. In addition, it is also invaluable
in measuring transmission line losses, connection losses, return loss, and other
parameters. Six optical units are available, depending on the wavelength and type
of optical fiber, making the MW9070B an economic choice for a wide range of applications.
Features
Compact
(smaller than footprint), lightweight (3.2 kg)
Simple operation with automated
fault measurement
Simultaneous waveform trace and event table display on
large LCD
Built-in 3.5 inch FDD (optional)
Wide dynamic range: 41.5/39.5
dB (MW0972C)
Short dead zone (MW0972C): 3 m (fresnel), 8 m (back-scattered)
High-speed real-time sweep to check fiber connections
Manual operation
for novice and experienced operation
Visual LD light source (option for units)
Emulation software runs on any personal computer under Windows environment
(sold separately)
There are both Singlemode and Multimode Optical Units available
Light source & power meter function (MW0972C optical power meter: Option)
CALL
Plenum Innerduct Today at (866) FIBER-21
For
All Your Test Equipment Needs