MaxCell® Edge Fabric Innerduct

MaxCell® Edge fabric innerduct is a specialized solution that enhances conduit capacity in network infrastructure while allowing room for future network expansions. Compared to rigid ducts, it has enabled the installation of significantly more cabling per conduit, with some instances reporting up to a 300% increase. In occupied conduits, MaxCell’s design facilitates the creation of new pathways, whether it involves bypassing existing cabling or traditional innerduct. This feature not only simplifies the process but also helps to reduce overall system costs.

 

 

MaxCell® Edge fabric innerduct is designed to maximize the capacity of conduits in network infrastructure while preserving space for future network deployments. New construction applications have yielded installation of up to 300% more cabling per conduit over rigid ducts. In occupied conduits, MaxCell’s design has allowed for easy pathway creation when overriding existing cabling or traditional innerduct while reducing total system cost.

  • Solves cabling issues for conduits, allowing a range of cable sizes
  • Enables overlay of cables in occupied conduits
  • Reduces or eliminates number of conduits required in new construction
  • Melting point of 419°F (215°C) (almost twice that of HDPE)
  • Halogen-free
  • Resistant to ground chemicals and petroleum products
  • Constructed of PET (Polyethylene Terephthalate) and Nylon 6
  • Patented fabric design may reduce pulling tension by up to 20% over previous MaxCell versions
  • Features color coded, pre-installed 1250LB pull tape in each cell* for 3″ and 4″ MaxCell. 1.25″, 1.75″ and 2″ MaxCell have pre-installed 1250LB VisT Glide Rope in each cell. 1.10″ MaxCell has pre-installed 600LB VisT Glide Rope in each cell.
  • Pre-lubed for lower friction during MaxCell and cable installation**
  • Manufactured in the U.S.A.

For quote please call: 866-650-DATA(3282) or email: sales@americanteledatastore.com

Product Information ——————————————————————————————————————————————

1INCH

 
PRODUCT #
MIN CONDUIT ID
CELLS
REPLACES
MAX CABLE DIAMETER PER CELL
MXE28101
1.10″
1 Cell
N/A
.40” (10mm)
MXE28102
1.10″
2 Cell
N/A
.40” (10mm)
MXE28103
1.10″
3 Cell
N/A
.40” (10mm)
MXE32121
1.25″
1 Cell
MXCM3301
.45” (12mm)
MXE32122
1.25″
2 Cell
MXCM3302
.45” (12mm)
MXE32123
1.25″
3 Cell
MXCM3303
.45” (12mm)
MXE36141
1.50″
1 Cell
N/A
.55” (14mm)
MXE36142
1.50″
2 Cell
N/A
.55” (14mm)
MXE36143
1.50″
3 Cell
N/A
.55” (14mm)
MXE44181
1.75″
1 Cell
N/A
.70” (18mm)
MXE44182
1.75″
2 Cell
N/A
.70” (18mm)
MXE44183
1.75″
3 Cell
N/A
.70” (18mm)
MXE44184
1.75″
4 Cell
N/A
.70” (18mm)

MAXCELL EDGE 1.10 INCHES SPEC SHEETS

MAXCELL EDGE 1.25 INCHES SPEC SHEETS

MAXCELL EDGE 1.5 INCH SPEC SHEETS

MAXCELL EDGE 1.75 INCHES SPEC SHEETS

—————————————————————————————————————————————————————-

2 INCH

 
PRODUCT #
MIN CONDUIT ID
CELLS
REPLACES
MAX CABLE DIAMETER PER CELL
MXE52221
2.00″
1 Cell
MXC2001
.85” (22mm)
MXE52222
2.00″
2 Cell
MXC2002
.85” (22mm)
MXE52223
2.00″
3 Cell
MXC2003
.85” (22mm)
MXE52224
1.25″
4 Cell
N/A
.85” (22mm)

MAXCELL EDGE 2 INCHES SPEC SHEET

—————————————————————————————————————————————————————-

3 INCH

 
PRODUCT #
MIN CONDUIT ID
CELLS
REPLACES
MAX CABLE DIAMETER PER CELL
MXE64283
3.00″
3 Cell
MXC3456
1.05” (28mm)

MAXCELL EDGE 3 INCHES 3- CELL SPEC SHEETS

MAXCELL EDGE 3 INCHES 4 – CELL SPEC SHEETS

—————————————————————————————————————————————————————-

4 INCH

 
PRODUCT #
MIN CONDUIT ID
CELLS
REPLACES
MAX CABLE DIAMETER PER CELL
MXE86383
4.00″
3 Cell
MXC4003
1.05” (38mm)

MAXCELL EDGE 4 INCHES 3 – CELL SPEC SHEET

MAXCELL EDGE 4 INCHES 4-CELL SPEC SHEET

Scroll to Top